A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Test-retest reliability and convergent validity of (R)-[C]PK11195 outcome measures without arterial input function. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: The PET radioligand (R)-[C]PK11195 is used to quantify the 18-kDa translocator protein (TSPO), a marker for glial activation. Since there is no brain region devoid of TSPO, an arterial input function (AIF) is ideally required for quantification of binding. However, obtaining an AIF is experimentally demanding, is sometimes uncomfortable for participants, and can introduce additional measurement error during quantification. The objective of this study was to perform an evaluation of the test-retest reliability and convergent validity of techniques used for quantifying (R)-[C]PK11195 binding without an AIF in clinical studies.

Methods: Data from six healthy individuals who participated in two PET examinations, 6 weeks apart, were analyzed. Regional non-displaceable binding potential (BP) values were calculated using the simplified reference tissue model, with either cerebellum as reference region or a reference input derived using supervised cluster analysis (SVCA). Standardized uptake values (SUVs) were estimated for the time interval of 40-60 min.

Results: Test-retest reliability for BP estimates were poor (80% of ICCs < 0.5). BP estimates derived without an AIF were not correlated with BP, total or specific distribution volume from the 2TCM using an AIF (all R < 12%). SUVs showed moderate reliability but no correlation to any other outcome measure.

Conclusions: Caution is warranted when interpreting patient-control comparisons employing (R)-[C]PK11195 outcome measures obtained without an AIF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6265355PMC
http://dx.doi.org/10.1186/s13550-018-0455-8DOI Listing

Publication Analysis

Top Keywords

test-retest reliability
12
reliability convergent
8
convergent validity
8
arterial input
8
input function
8
validity r-[c]pk11195
4
r-[c]pk11195 outcome
4
outcome measures
4
measures arterial
4
function purpose
4

Similar Publications