A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of various agitation methods on adhesive layer formation of HEMA-free universal dentin adhesive. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This study evaluates the effects of various agitation methods on the adhesive layer formation of a new HEMA-free universal dentin adhesive. The µTBS of the universal adhesive, G-Premio BOND in the self-etch mode was evaluated using three agitation methods [passive agitation (PA), active agitation (AA), ultrasonic agitation (UA)], with and without aging treatment. Two-way analysis of variance revealed that aging treatment was not a statistically significant factor. Tukey's HSD test showed significant differences based on the application method, UA>AA>PA. TEM images of the PA group revealed multiple water blisters in the adhesive layers; AA and UA groups presented significantly less or no blisters within the adhesive layers; thus, AA and UA groups exhibited better bonding performance for the HEMA-free universal adhesive. It is assumed that the entrap ped blisters can be reduced with the active application of dentin adhesive, and thus improving the bonding performance.

Download full-text PDF

Source
http://dx.doi.org/10.4012/dmj.2018-031DOI Listing

Publication Analysis

Top Keywords

agitation methods
12
hema-free universal
12
dentin adhesive
12
adhesive
9
methods adhesive
8
adhesive layer
8
layer formation
8
formation hema-free
8
universal dentin
8
universal adhesive
8

Similar Publications