Introduction: Frozen section helps in rapid intra-operative diagnosis. It is commonly used during surgical procedures to detect malignancy so that modifications of surgery can be decided at the time of surgery on the table. Frozen section is also performed for evaluation of surgical margins and detection of lymph node metastasis. In addition it is applied for detection of unknown pathological processes.The objective of this study was to assess the accuracy of frozen section diagnosis in comparison to gold standard histopathological diagnosis and to find concordance and discordance rate of frozen section with histopathological report.
Methods: This was a cross sectional study of 41 frozen section samples done in the department of pathology of BP Koirala Institute of Health Sciences from September 2014 to August 2015. All frozen section samples with their permanent tissue samples sent for final histopathological evaluation were included in the study.
Results: The overall accuracy of frozen section diagnosis was 97%. The sensitivity was 94%, specificity was 87%, positive predictive value was 90% and negative predictive value was 93%. The concordance rate was 90.2% and the discordance rate was 9.8%.
Conclusions: The results of frozen section varied in different organ systems and the common cause of discrepancy in our study were the gross sampling error and the interpretational error.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8997296 | PMC |
Nanomicro Lett
September 2025
Nanomaterials & System Lab, Major of Mechatronics Engineering, Faculty of Applied Energy System, Jeju National University, Jeju, 63243, Republic of Korea.
Wearable sensors integrated with deep learning techniques have the potential to revolutionize seamless human-machine interfaces for real-time health monitoring, clinical diagnosis, and robotic applications. Nevertheless, it remains a critical challenge to simultaneously achieve desirable mechanical and electrical performance along with biocompatibility, adhesion, self-healing, and environmental robustness with excellent sensing metrics. Herein, we report a multifunctional, anti-freezing, self-adhesive, and self-healable organogel pressure sensor composed of cobalt nanoparticle encapsulated nitrogen-doped carbon nanotubes (CoN CNT) embedded in a polyvinyl alcohol-gelatin (PVA/GLE) matrix.
View Article and Find Full Text PDFAnal Chim Acta
November 2025
Department of Breast Surgery, General Surgery Center, First Hospital of Jilin University, Changchun, PR China. Electronic address:
Background: Breast-conserving surgery (BCS) is the primary surgical approach for patients with breast cancer. The accurate determination of surgical margins during BCS is critical for patient prognosis; however, time constraints and limitations in current pathological techniques often prevent pathologists from performing this assessment intraoperatively. The inability to reliably assess margins during surgery can lead to incomplete tumor removal and the need for additional surgeries.
View Article and Find Full Text PDFJ Microbiol Methods
September 2025
Dynamics of Respiratory Infections Group, Helmholtz Centre for Infection Research-HZI Braunschweig, Braunschweig, Germany; Department of Respiratory Medicine and Infectious Diseases, Hannover Medical School, German Center for Lung Research (DZL), BREATH, Hannover, Germany.
Purpose: The accuracy of oral microbiome research depends significantly on specimen sampling protocols, as well as their storage and preservation. Traditional methods, such as freezing, may not only involve logistical hurdles but can also impact the quality of microbial data, leading to difficulties in the comparability between different studies. This study evaluates the effectiveness of the room temperature nucleic acid preservation protocol using DNA/RNA Shield buffer as compared to standard freezing in preserving oral microbial communities over the course of 7 days.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
September 2025
Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, 7522 NB, the Kingdom of the Netherlands. Electronic address:
In orthopaedic surgical procedures, bone cutting is often performed with an oscillating saw. Achieving an optimal cut requires high accuracy, low temperature, minimal surgeon effort, and time efficiency, all of which may be influenced by the forces applied on the sawing device, and the microstructure of the cut bone. The relation between bovine bone microstructure and sawing forces has been studied.
View Article and Find Full Text PDFEur J Breast Health
September 2025
Department of Pathology, İstanbul Faculty of Medicine, İstanbul University, İstanbul, Türkiye.
Objective: Sentinel lymph node biopsy (SLNB) is a key procedure for evaluating axillary lymph node status in early breast cancer, offering lower morbidity than axillary lymph node dissection. Intraoperative evaluation (IOE) of sentinel lymph nodes (SLNs) with methods like frozen section (FS) and imprint cytology (IC) aid in making immediate surgical decisions, although IOE accuracy may vary due to several factors.
Materials And Methods: This retrospective study involved 2,528 patients with invasive breast cancer who underwent SLNB at a single institution from 2012 to 2024.