Objectives: To evaluate the diagnostic accuracy of color Doppler imaging (CDI) and contrast-enhanced ultrasound (CEUS) for diagnosing carotid ulceration, having multi-detector computed tomography angiography (MDCTA) as the reference method.
Methods: Patients with carotid disease referred for ultrasound (US), either due to the occurrence of neurovascular symptoms or for screening purposes, were included in this study if at least one plaque causing moderate (50-69%) or severe (70-99%) internal carotid artery stenosis was detected. Carotid US with CDI technique, CEUS, and MDCTA were performed in all patients, investigating the presence of ulceration. The agreement between modalities was evaluated using kappa statistics.
Results: The study population included 54 patients (median age 62 years, inter-quartile range 16.2) and 66 carotid arteries. The mean degree of stenosis was 68.5% (SD 12.2%) while 47.1% of plaques were symptomatic. MDCTA characterized 28.8% of plaques as smooth, 45.5% irregular, and 24.3% ulcerated. Flow reversal was detected with CDI in 65.5% of ulcerations, while swirling of the microbubbles and neovessels adjacent to the ulcer were detected with CEUS in 17.64%. The agreement for ulceration diagnosis was moderate between CDI and CEUS (kappa 0.473) and between CDI and MDCTA (kappa 0.473) and very good between CEUS and MDCTA (kappa 0.921). The sensitivity, specificity, and positive and negative predictive values of CDI for the diagnosis of ulceration were 41.2%, 97.95%, 87.5%, 82.8% respectively, while CEUS respective measures were 94.1%, 97.95%, 94.1%, and 97.95%.
Conclusion: CEUS outperformed CDI in terms of agreement with MDCTA and diagnostic accuracy for the diagnosis of ulcerated carotid plaque.
Key Points: • Superficial ulceration is a significant feature of carotid plaque vulnerability. • Color Doppler imaging has the potential to demonstrate carotid plaque ulceration but is characterized by limited sensitivity and moderate agreement with the reference method of multi-detector computed tomography angiography. • Contrast-enhanced ultrasound outperforms color Doppler imaging in terms of sensitivity for the detection of carotid plaque ulceration and in agreement with the reference method of multi-detector computed tomography angiography.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-018-5773-8 | DOI Listing |
Turk J Pediatr
September 2025
Department of Anesthesiology, All India Institute of Medical Sciences, Patna, India.
Background: Umbilical arterial catheterisation is a common intervention performed in the neonatal intensive care unit (NICU) especially in extremely preterm and extremely low birth weight neonates. Rarely catheter fracture or breakage can occur, leaving behind part of the catheter in the aorta. A handful of cases have been reported in the literature, with the majority being managed surgically.
View Article and Find Full Text PDFScand J Rheumatol
September 2025
Department of Rheumatology and Clinical Immunology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Objective: To investigate the reliability of lacrimal gland ultrasound (LGUS) in patients with clinically suspected Sjögren's disease (SjD).
Method: Of 41 consecutive patients with clinically suspected SjD, 28 were diagnosed with SjD and 13 were classified as non-SjD. Forty patients were scored for bilateral lacrimal gland (LG) B-mode evaluation; LGs were 'not visible' in one case.
Medicine (Baltimore)
September 2025
Al Mouwasat University Hospital, Damascus University, Damascus, Syria.
Rationale: Systemic sclerosis (SS) is an immune-mediated connective disease characterized by skin fibrosis, microvascular damage, and multisystem manifestations. One of the most important processes in connective tissue disorders is vasculitis. The clinical findings can differ when the disease is presented with an antineutrophil cytoplasmic antibody.
View Article and Find Full Text PDFUltraschall Med
September 2025
Division of Prenatal Medicine, Gynecological Ultrasound and Fetal Surgery, Department of Obstetrics and Gynecology, University Hospital, Cologne, Germany.
Approximately 0.8 % of all children are born with heart defects, with the prenatal incidence naturally being even higher. Among all congenital heart defects (CHD), conotruncal anomalies are the most common critical heart defects - after ventricular and atrial septal defects.
View Article and Find Full Text PDFClin Case Rep
September 2025
Department of Radiation Oncology, School of Medicine, Shahid Rajayee Hospital Babol University of Medical Sciences Babol Iran.
Primary cardiac lymphoma (PCL) is one of the rarest primary malignancies of the heart. This report describes a rare presentation of diffuse large B-cell lymphoma (DLBCL) in a 61-year-old woman from Iran who presented with weakness, dyspnea, and bilateral lower extremity edema, especially on the right side that progressively worsened over 2 years. Initial diagnostic workup, including laboratory tests, color Doppler ultrasound, and echocardiography, revealed a large immobile mass attached to the RA wall.
View Article and Find Full Text PDF