Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2018.09.016DOI Listing

Publication Analysis

Top Keywords

hip knee
4
knee prevention
4
prevention prosthesis
4
prosthesis factors
4
factors proceedings
4
proceedings international
4
international consensus
4
consensus orthopedic
4
orthopedic infections
4
hip
1

Similar Publications

Background: Differentiating periprosthetic joint infections (PJI) from aseptic failure is challenging in total joint arthroplasty. To date, there is no consensus about the most accurate criteria to diagnose PJI. The current study compares common diagnostic PJI criteria.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the functional and radiological outcomes, complications and procedure survival in patients with posttraumatic tibial plateau deformities treated with unicondylar intra-articular tibial plateau osteotomy (UIATPO), comparing medial and lateral approaches.

Methods: A retrospective study was conducted on all patients with posttraumatic intra-articular tibial plateau deformities who underwent surgical correction at a single centre between 2016 and 2022, with a minimum follow-up of 24 months. Patient characteristics, radiological correction, patient-reported outcome measures (PROMs), including the Lysholm and knee injury and osteoarthritis outcome score (KOOS), and complications were recorded.

View Article and Find Full Text PDF

Image-based robotics enhance precision and efficiency in lateral UKA: A comparative study of 135 UKAs.

Knee Surg Sports Traumatol Arthrosc

September 2025

Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital, Lyon, France.

Purpose: Robotic-assisted lateral unicompartmental knee arthroplasty (UKA) remains technically demanding due to the complex biomechanics of the lateral compartment. Image-based (IBRA) and imageless (ILRA) robotic systems have both demonstrated superior accuracy compared to conventional mechanical instrumentation, but have not yet been directly compared in lateral UKA. This study aimed to evaluate their respective accuracy and surgical efficiency.

View Article and Find Full Text PDF

Purpose: This analysis evaluated whether logistic regression and machine learning models could predict achievement of the minimal clinically important difference (MCID) for the International Hip Outcome Tool (iHOT-12) and Hip Outcome Score (HOS) at 6 and 12 months following hip arthroscopy.

Methods: Data from the multicenter Femoroacetabular Impingement RandomiSed controlled Trial and its embedded prospective cohort were used. A total of 309 patients (mean ± SD age 34.

View Article and Find Full Text PDF

Kinematic alignment is increasingly adopted in total knee arthroplasty (TKA) as a patient-specific strategy to restore native joint anatomy. However, its reliance on static radiographic measurements may not adequately reflect real-world functional biomechanics. This editorial underscores the importance of complementing static assessment with kinetic principles.

View Article and Find Full Text PDF