98%
921
2 minutes
20
Background: Limited reports have documented the effect cardiac implantable electronic devices (CIEDs) have on arteriovenous (AV) access patency. Current recommendations suggest placing the access on the contralateral side of the CIEDs, as there is concern for increased central venous stenosis and access failure. The goal of this study is to review our single-center AV access patency rates for dialysis patients with an ipsilateral or contralateral side CIED.
Methods: A retrospective review was performed from 2008 to 2016 at a single institution identifying all patients who have received a CIED and the diagnosis of end-stage renal disease (ESRD). Medical records were queried to identify each patient's dialysis access and whether it was ipsilateral or contralateral to the CIED. Primary outcomes of study were primary and secondary patency rates.
Results: A total of 44 patients were identified to have ESRD and CIED. Of these patients, 28 patients with fistulas or grafts (13 ipsilateral and 15 contralateral) had follow-up with regards to their AV access. There were 3 primary failures in both groups. For patients who had the CIED placed after already starting the dialysis, patency was based on when the cardiac device was implanted. Primary patency for ipsilateral and contralateral access was 20.2 and 22.2 months, respectively. With secondary interventions, ipsilateral and contralateral mean patency was 39 and 48.8 months, respectively. Six-month and 1-year primary patency for arteriovenous fistula or arteriovenous graft on patients with ipsilateral access was 69.2% and 53.8%, respectively. Ipsilateral 1-year cumulative patency was 39 months.
Conclusions: CIED may lead to stenosis or occlusion to one's AV access; however, primary assisted and secondary patency rates are still acceptable at 6 months and 1 year compared to Kidney Disease Outcomes Quality Initiative guidelines. Despite a CIED, a surgeon's algorithm should not lead to the abandonment of an ipsilateral access if the central venous system is patent.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8439285 | PMC |
http://dx.doi.org/10.1016/j.avsg.2018.10.003 | DOI Listing |
PLoS Comput Biol
September 2025
Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado, United States of America.
Deciphering the source of an embolism is a common challenge encountered in stroke treatment. Carotid stenosis is a key source of embolic strokes. Carotid interventions can be indicated when a patient has greater than 50% stenosis in the carotid ipsilateral to the cerebral infarction, which is designated as the symptomatic carotid.
View Article and Find Full Text PDFJ Craniofac Surg
September 2025
Department of Plastic and Reconstructive Surgery, Hanoi Medical University.
Introduction: Complex soft tissue injuries in the facial area can arise from various causes. Surgeons face significant challenges when reconstructing these injuries, as they must select appropriate materials based on texture and color, while also considering their composition and properties. The anterolateral thigh (ALT) flap has emerged as a versatile option in clinical reconstructive surgery, offering many advantages over other free flaps.
View Article and Find Full Text PDFNeuroimage Rep
September 2025
School of Psychology, Faculty of Medicine and Health, University of Leeds, LS2 9JT, UK.
Background: Theta Burst Stimulation (TBS) is a form of non-invasive brain stimulation that can induce neuroplastic changes in the underlying intracortical areas. It has significant potential in clinical and research settings for modulating cognitive and motor performance. Little is known about how TBS affects oxygenations levels within and across brain hemispheres during stimulation of the Dorsolateral Prefrontal Cortex (DLPFC).
View Article and Find Full Text PDFFront Neurol
August 2025
McGovern Medical School, Department of Neurology, The University of Texas Health Houston, Houston, TX, United States.
Background: Recent trials of large core thrombectomy have shown that our traditional understanding of infarct characteristics and reperfusion benefit may be incomplete for patients with acute ischemic stroke (AIS). The Alberta Stroke Program Early CT Score (ASPECTS) has wide inter-rater variability, and modern studies have also shown that reperfusion therapies can benefit some patients regardless of the ASPECTS. Reproducible imaging metrics that account for the degree of hypo-attenuation on non-contrast computed tomography (NCCT) may be better suited to guide treatments.
View Article and Find Full Text PDFInt J Surg Case Rep
September 2025
Department of Orthopedic Surgery, Faculty of Medicine, Balamand University, Beirut, Lebanon; Department of Orthopedics and Traumatology, Clemenceau Medical Center, Beirut, Lebanon.
Introduction And Importance: Brown-Sequard syndrome (BSS) is a rare spinal cord hemisection syndrome characterized by ipsilateral weakness with contralateral loss of pain and temperature. Cervical intradural disc herniation (CIDH), an extremely rare phenomenon, is an uncommon etiology of BSS. Only around 50 cases of CIDH have been reported in the literature to date, including our own.
View Article and Find Full Text PDF