A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

G-EYE colonoscopy is superior to standard colonoscopy for increasing adenoma detection rate: an international randomized controlled trial (with videos). | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Aims: Colorectal cancer (CRC) is largely preventable with routine screening and surveillance colonoscopy; however, interval cancers arising from precancerous lesions missed by standard colonoscopy still occur. An increased adenoma detection rate (ADR) has been found to be inversely associated with interval cancers. The G-EYE device includes a reusable balloon integrated at the distal tip of a standard colonoscope, which flattens haustral folds, centralizes the colonoscope's optics, and reduces bowel slippage. The insufflated balloon also aims to enhance visualization of the colon during withdrawal, thereby increasing the ADR.

Methods: In this randomized, controlled, international, multicenter study (11 centers), patients (aged ≥50 years) referred to colonoscopy for screening, surveillance, or changes in bowel habits were randomized to undergo either balloon-assisted colonoscopy by using an insufflated balloon during withdrawal or standard high-definition colonoscopy. The primary endpoint was the ADR.

Results: One thousand patients were enrolled between May 2014 and September 2016 to undergo colonoscopy by experienced endoscopists; 803 were finally analyzed (standard colonoscopy n = 396; balloon-assisted colonoscopy n = 407). Baseline parameters were similar in both groups. Balloon-assisted colonoscopy provided a 48.0% ADR compared with 37.5% in the standard colonoscopy group (28% increase; P = .0027). Additionally, balloon-assisted colonoscopy provided for a significant increase in detection of advanced (P = .0033) flat adenomas (P < .0001) and sessile serrated adenomas/polyps (P = .0026).

Conclusion: Balloon-assisted colonoscopy yielded a higher ADR and increased the detection of advanced, flat, and sessile serrated adenomas/polyps when compared with standard colonoscopy. Improved detection by the G-EYE device could impact the quality of CRC screening by reducing miss rates and consequently reducing interval cancer incidence. (Clinical trial registration number: NCT01917513.).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2018.09.028DOI Listing

Publication Analysis

Top Keywords

standard colonoscopy
16
balloon-assisted colonoscopy
16
colonoscopy
12
adenoma detection
8
detection rate
8
randomized controlled
8
screening surveillance
8
interval cancers
8
insufflated balloon
8
colonoscopy n =
8

Similar Publications