Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Objective: The conventional myoelectric control scheme of hand prostheses provides a high level of robustness during continuous use. Typically, the electrical activity of an agonist/antagonist muscle pair in the forearm is detected and used to control either opening/closing or rotation of the prosthetic hand. The translation of more sophisticated control approaches (e.g. regression-based classifiers) to clinical practice is limited mainly because of their lack of robustness in real-world conditions (e.g. due to different arm positions). We therefore explore a new hybrid approach, in which a second degree of freedom (DOF) controlled by the myoelectric activity of the posterior auricular muscles is added to the conventional forearm control. With this, an independent, simultaneous and proportional control of rotation and opening/closing of the hand is possible.
Approach: In this study, we compared the hybrid auricular control system (hACS) to the two most commonly used control techniques for two DOF. Ten able-bodied subjects and one person with transradial amputation performed two standardizes tests in three different arm positions.
Main Results: Subjects controlled a hand prosthesis significantly more rapidly and more accurately using the hACS. Moreover, the robustness of the system was not influenced by different arm positions.
Significance: The hACS therefore offers an alternative solution for simultaneous and proportional myoelectric control of two degrees of freedom that avoids several robustness issues related to machine learning based approaches.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1741-2552/aad727 | DOI Listing |