A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of sampling procedure on the quality control metrics of cytoscan HD array for studying cytogenetic aspects of colorectal cancer. | LitMetric

Effect of sampling procedure on the quality control metrics of cytoscan HD array for studying cytogenetic aspects of colorectal cancer.

Int J Health Sci (Qassim)

King Abdullah International Medical Research Center, King Saud Bin Abdulaziz University for Health Sciences, King Abdulaziz Medical City, Riyadh, Ministry of National Guard Health Affairs, Saudi Arabia.

Published: January 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: The method of colorectal cancer (CRC) tissue sampling would affect its molecular profile and the downstream processing. In this study, we described the impact of CRC tissue sampling procedures on the quality control (QC) metrics of cytoscan HD array.

Methods: We employed a high-resolution cytoscan HD microarray platform to investigate the chromosomal aberrations that could be associated with CRC. We compared the tissue extraction procedures and their impact on the QC parameters from the cytoscan HD array determined by chromosome analysis software (Suite3.1). Median of absolute values of all pairwise differences (MAPD), waviness-standard deviation (Waviness-SD), and single nucleotide polymorphism QC (SNPQC) were the QC parameters that were analyzed.

Results: From 67 patients, we collected 843 colorectal tissues. Of these, 65.7% were obtained through endoscopic procedures, and the rest was after surgical resections. The mean transit time between tissue excision and preservation was 26 ± 15.5 and 74.6 ± 24.8 min, respectively. The tissues extracted from the surgical procedure showed mean MAPD of 0.28 ± 0.06 compared to 0.24 ± 0.06, for endoscopy, = 0.005, degree of waviness-SD of 0.20 ± 0.1 compared to 0.2 ± 0.1, = 0.64, and SNPQC of 9.6 ± 4.2 compared to 11.1 ± 4.6, = 0.23.

Conclusions: This report provides objective results that can help in tissue sampling intended to be used for DNA based molecular studies. Tissue collection protocol should be optimized to support microarray-analysis methods. Tissue extraction from endoscopic procedures had faster transit time and relatively better quality metrics outcome than surgical procedures. However, surgical procedures have less refusal rate, higher tissue quantity, and less negative results for malignancy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6040854PMC

Publication Analysis

Top Keywords

tissue sampling
12
quality control
8
control metrics
8
metrics cytoscan
8
cytoscan array
8
colorectal cancer
8
tissue
8
crc tissue
8
tissue extraction
8
endoscopic procedures
8

Similar Publications