A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of Inhalation Flow Rate on Mass-Based Plume Geometry of Commercially Available Suspension pMDIs. | LitMetric

Effect of Inhalation Flow Rate on Mass-Based Plume Geometry of Commercially Available Suspension pMDIs.

AAPS J

Division of Molecular Pharmaceutics and Drug Delivery, College of Pharmacy, The University of Texas at Austin, 2409 University Ave, A1920, Austin, Texas, 78712, USA.

Published: July 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Although high-speed laser imaging is the current standard to characterize the plume angle of suspension-based pressurized metered dose inhalers (pMDIs), this method is limited by the inability to identify the drug content in a droplet and simulate inhalation flow. The Plume Induction Port Evaluator (PIPE) is a modified induction port for cascade impactors that allows for the calculation of the angle of a plume based on direct drug mass quantification rather than indirect droplet illumination under airflow conditions. The objective of this study was to investigate the use of the PIPE apparatus to evaluate the effect of airflow on the Mass Median Plume Angle (MMPA) of commercially available suspension-based pMDIs (Ventolin® HFA, ProAir® HFA, and Proventil® HFA). Deposition patterns within PIPE were log-normally distributed allowing for the calculation of the MMPA for the three suspension products. Mass-based plume angles were significantly smaller (narrower angle) when inhalation airflow was used compared to no flow conditions (reduction of MMPA was 8, 16, and 13% for Ventolin® HFA, ProAir® HFA, and Proventil® HFA, respectively). Additionally, new parameters for characterizing plume geometry were calculated (MMPA ex-actuator and plume orientation). Mass-based plume angles of the suspension-based pMDI formulations were highly reproducible and demonstrated the effect of inhalation flow rate. These results suggest that plume geometry tests should be evaluated under flow conditions which is not possible using current methodologies. Graphical Abstract ᅟ.

Download full-text PDF

Source
http://dx.doi.org/10.1208/s12248-018-0241-6DOI Listing

Publication Analysis

Top Keywords

inhalation flow
12
mass-based plume
12
plume geometry
12
plume
10
flow rate
8
plume angle
8
induction port
8
ventolin® hfa
8
hfa proair®
8
proair® hfa
8

Similar Publications