A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Bronchoscopy Using Virtual Navigation and Endobronchial Ultrasonography with a Guide Sheath (EBUS-GS) with or without Fluoroscopy for Peripheral Pulmonary Lesions. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Endobronchial ultrasonography and guide sheath (EBUS-GS) technique has high diagnostic yield in lung nodules. Virtual bronchoscopic navigation (VBN) can lead bronchoscope to the target bronchi. The aim of this prospective study was to compare the diagnostic yield of two bronchoscopic procedures: bronchoscopy under EBUS-GS and VBN with or without x-ray fluoroscopy in small peripheral pulmonary lesions (PPLs, ≤30mm) with apparent CT-bronchus sign.

Methods: 31 patients with PPLs which had apparent CT-bronchus sign were randomly assigned to the X-ray or the non-X-ray groups (18 with and 13 without fluoroscopy) between September 1, 2012, and September 30, 2015. A bronchoscope was introduced into the target bronchus using the VBN system. Sites of specimen sampling were verified using EBUS-GS with or without fluoroscopy.

Results: The overall diagnostic yield was 83.3% in the X-ray and 69.2% in the non-X-ray group. The diagnostic yield of malignancy was 88.2% and 81.8%, respectively. The duration of the examination and time elapsed until the first EBUS visualization were similar in the X-ray and the non-X-ray group (9.0 (5.8-20.) min vs 11.0 (5.3-17.3) min, and 2.5 (1.3-14.2) min vs 4.1 (1.4-8.1) min, respectively). The fluoroscopy exposure time was 3.7 (2.9-10.56) min. The only adverse event was mild pneumothorax in a patient from the non-X-ray group, who had consequent TBB under fluoroscopy.

Conclusions: There was a possibility that VBN-guided EBUS-transbronchial diagnosis without fluoroscopy might be equivalent to that under fluoroscopy. Further multi-center randomized study may be desired. (UMIN000008592).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6192820PMC