A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Changes in corneal biomechanical properties after 24 hours of continuous intraocular pressure monitoring using a contact lens sensor. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: This study was designed to assess changes in corneal topography and biomechanics after intraocular pressure (IOP) monitoring using the Triggerfish contact lens sensor (CLS).

Methods: For this prospective study, 30 eyes of 30 subjects: 14 healthy subjects (G1) and 6 glaucoma patients (G2), were recruited for 24 hours of continuous IOP monitoring using the CLS. The following measurements were taken before CLS fitting and after lens removal: maximum keratometry (Kmax), mean keratometry (MK), and corneal astigmatism (Cyl) measured through Pentacam corneal topography, and the corneal biomechanical variables corneal hysteresis (CH) and corneal resistance factor (CRF) measured with the Ocular Response Analyzer (ORA).

Results: Pentacam data revealed significant changes after CLS removal in Kmax (+3.14 ± 2.46 D, p = 0.002), MK (+0.52 ± 0.63 D, p = 0.02), and Cyl (+0.48 ± 0.53 D, p = 0.019) in G1; and Kmax (+1.38 ± 1.43 D, p = 0.002) in G2. The changes observed were more pronounced in G1 than in G2 but differences were not significant. The ORA results indicated higher CH (11.35 ± 2.42 vs 8.17 ± 2.09) and CRF (10.3 ± 2.03 vs 9.1 ± 1.81) before lens fitting in G1 than G2, while no significant changes were produced after CLS removal in either group.

Conclusions: The use of CLS for IOP monitoring over 24 hours caused topographic changes in both healthy subjects and glaucoma patients. No changes were produced in corneal biomechanics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcjo.2017.10.028DOI Listing

Publication Analysis

Top Keywords

iop monitoring
12
changes corneal
8
corneal biomechanical
8
hours continuous
8
intraocular pressure
8
contact lens
8
lens sensor
8
corneal topography
8
healthy subjects
8
subjects glaucoma
8

Similar Publications