Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Objective: The aim of this study was to compare the pharmacokinetics (PK) and safety profiles of a fixed-dose combination (FDC) formulation of fimasartan, amlodipine, and rosuvastatin with the co-administration of the two products by using a replicated crossover study design in healthy male subjects.
Results: This was an open-label, randomized, three-sequence, three-period replicated crossover study in healthy male subjects. The replicated crossover design was done because of high coefficient of variation of PK parameter for fimasartan, that is, >30%. With a 14 days washout period, an FDC tablet containing 60 mg fimasartan, 10 mg amlodipine, and 20 mg rosuvastatin was administered only once, and separate formulations of fimasartan/amlodipine 60 mg/10 mg FDC tablet and 20 mg rosuvastatin tablet administered twice. Blood samples were collected up to 72 hours following drug administration. The plasma concentrations of fimasartan, amlodipine, and rosuvastatin were measured by liquid chromatography tandem mass spectrometry. Safety was assessed by evaluating vital signs, clinical laboratory parameters, physical examinations, and medical interviews.
Results: The geometric mean ratios and 90% confidence intervals (CIs) for the maximum plasma concentration (C) and area under the curve from time zero to the last measurable sampling time (AUC) were 1.0776 (0.9201-1.2622) and 0.9978 (0.9538-1.0439) for fimasartan, 1.0038 (0.9782-1.0301) and 1.0055 (0.9828-1.0288) for amlodipine, and 1.0006 (0.9290-1.0776) and 0.9986 (0.9532-1.0461) for rosuvastatin, respectively. A total of 22 adverse events (AEs) were reported by 60 subjects; there were no significant differences in the incidence of AEs between the two groups.
Conclusion: The 90% CI of the C of fimasartan was within the widened acceptance limit, ln(0.6984)-ln(1.4319). The 90% CIs of the other PK parameters for drugs were between ln(0.8) and ln(1.25). These results suggest that the FDC formulation is pharmacokinetically bioequivalent and has a similar safety profile, to the co-administration of its three constituent drugs.