A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Density and electron density of aqueous cryoprotectant solutions at cryogenic temperatures for optimized cryoprotection and diffraction contrast. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The glass-phase densities at T = 77 K of aqueous solutions of the common cryoprotective agents (CPAs) methanol, ethanol, 2-propanol, glycerol, 2-methyl-2,4-pentanediol (MPD), ethylene glycol, polyethylene glycol 200 and polypropylene glycol 425 were measured as a function of CPA concentration. Individual drops with volumes as small as ∼65 pl were rapidly cooled to achieve the glass phase, and their densities at T = 77 K were determined by cryoflotation. These densities were used to determine the glass-phase electron density of each solution and its volume thermal contraction between room temperature and 77 K. When combined with data for the critical cooling rates required to achieve the glass phase versus CPA concentration, these yield alternative measures of cryoprotectant effectiveness. These reference data will aid in minimizing sample stresses and mechanical damage in cryocrystallography, in cryogenic temperature X-ray imaging and in vitrification-based cryopreservation protocols, and in maximizing electron-density contrast between cryoprotectant solutions and biomolecules in cryogenic temperature small-angle X-ray scattering experiments and cryo-electron microscopy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5930352PMC
http://dx.doi.org/10.1107/S2059798318003078DOI Listing

Publication Analysis

Top Keywords

electron density
8
cryoprotectant solutions
8
densities 77 k
8
cpa concentration
8
achieve glass
8
glass phase
8
cryogenic temperature
8
density electron
4
density aqueous
4
aqueous cryoprotectant
4

Similar Publications