A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Enzyme-free Target Recycling and Double-Output Amplification System for Electrochemiluminescent Assay of Mucin 1 with MoS Nanoflowers as Co-reaction Accelerator. | LitMetric

Enzyme-free Target Recycling and Double-Output Amplification System for Electrochemiluminescent Assay of Mucin 1 with MoS Nanoflowers as Co-reaction Accelerator.

ACS Appl Mater Interfaces

Key Laboratory of Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering , Southwest University, Chongqing 400715 , People's Republic of China.

Published: May 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this work, a sensitive electrochemiluminescent assay of mucin 1 (MUC1) was developed with the advantages of target recycling amplification strategy and effective MoS nanoflower (MoS NF)-based signal probe. Briefly, the target MUC1 triggered enzyme-free recycling and a double-output amplification process was executed to acquire masses of single-stranded DNA as a mimic target, which further participated in the catalytic hairpin assembly process for signal amplification. Meanwhile, MoS NFs were prepared as an effective co-reaction accelerator, which not only possessed excellent catalytic performance for HO decomposition to largely enhance the luminous intensity of N-(aminobutyl)- N-(ethylisoluminol) (ABEI)-HO electrochemiluminescence system but also offered a desirable platform for ABEI-functionalized Ag nanoparticles (ABEI-Ag complexes) loading via Ag-S binding. The experimental results showed the proposed aptasensor had a good linear relationship in the range of 1 fg/mL to 10 ng/mL for MUC1 detection and the limit of detection was 0.58 fg/mL (S/N = 3). In addition, the aptasensor had nice stability and selectivity and huge potential to be applied in clinical research.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.8b02262DOI Listing

Publication Analysis

Top Keywords

target recycling
8
recycling double-output
8
double-output amplification
8
electrochemiluminescent assay
8
assay mucin
8
co-reaction accelerator
8
enzyme-free target
4
amplification
4
amplification system
4
system electrochemiluminescent
4

Similar Publications