Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Computed tomography with its excellent spatial and temporal resolution remains a valuable diagnostic modality in pediatrics. On the other hand an increasing attention has been placed on the radiation risks associated with CT imaging, especially in children. In recent years, many advances in CT hardware and software, for example, automatic exposure control tools and iterative reconstruction techniques, have allowed for a reduction of applied radiation doses while maintaining image quality. The purpose of this paper is to present our protocol for chest CT imaging in the youngest age group, together with a pictorial review of congenital pathologies of the chest, and to emphasize factors that optimize postnatal CT imaging in infants. In our opinion, modern CT imaging with the use of dose reduction techniques and iterative reconstructions allows for a proper visualization of chest pathologies in small children, which has no influence on observer performance. The presented review of low-dose diagnostic images of a wide spectrum of congenital pathologies may serve as an example of routine utilization of the current concepts in pediatric CT optimization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5894012PMC
http://dx.doi.org/10.12659/PJR.900615DOI Listing

Publication Analysis

Top Keywords

chest pathologies
8
computed tomography
8
pictorial review
8
congenital pathologies
8
postnatal evaluation
4
evaluation congenital
4
chest
4
congenital chest
4
pathologies
4
pathologies low-dose
4

Similar Publications

Objective: Identify social/metabolic risk factors associated with subsequent diagnosis of adrenal adenoma.

Design: Population-based historical case-control study.

Methods: Cases were adult patients diagnosed with an adrenal adenoma between 2005-2017 with no overt hormone excess.

View Article and Find Full Text PDF

Objective: Present study aimed to determine the demographic, epidemiological and pathological features of human cystic echinococcosis (CE) cases using patients' hospital based clinical history from 2012-2023.

Methods: The current retrospective study was conducted from June-December and aimed to investigate the incidence of human CE in Pakistan. A total of 74 surgically confirmed patients' data was retrieved from the hospital records.

View Article and Find Full Text PDF

Purpose: Teleangiectatic osteosarcoma is a histologic subtype of osteosarcoma that can mimic aneurysmal bone cysts and has so far been incompletely characterized.

Patients And Methods: We used the database of the Cooperative Osteosarcoma Study Group COSS (patient-registration 1980-2019) to better understand this rare histologic variant.

Results: 223 eligible patients were identified, 164 having reference pathology (median age 15.

View Article and Find Full Text PDF

Objective: Persistent pulmonary air leak happens in a minority of patients with various thoracic pathologies. Spiration (Olympus America Inc.) bronchial valves (BVs) are approved by the Food and Drug Administration under Humanitarian Use Device status to treat persistent air leak after lung resection.

View Article and Find Full Text PDF

Sparing effects of FLASH irradiation in patient-derived lung tissue.

Radiother Oncol

September 2025

Institut Curie, Inserm U1021-CNRS UMR 3347, University Paris-Saclay, PSL Research University, Centre Universitaire, 91405 Orsay Cedex, France. Electronic address:

Background And Purpose: Radiation toxicities, such as pneumonitis and fibrosis, are major limitations affecting patients' quality of life. Developed a decade ago, FLASH radiotherapy is an innovative method that, by delivering radiation at ultrafast dose rate, reduces radiation toxicities on healthy tissue while preserving the anti-tumoral effect of radiotherapy. This so-called FLASH effect has been described in different preclinical models but has not been observed in human tissue.

View Article and Find Full Text PDF