Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Ultra-low-wear polyethylene (ULWPE) is a new type polyethylene made by experts who are from China petrochemical research institute, which is easy to process and implant. Preliminary test showed it was more resistant to wear than that of Ultra-high-molecular weight polyethylene (UHMWPE). The purpose of the research is to study biocompatibility, bio-tribological properties and debris characterization of ULWPE. Cytotoxicity test, hemolysis test, acute/chronic toxicity and muscular implantation test were conducted according to national standard GB/T-16886/ISO-10993 for evaluation requirements of medical surgical implants. We obtained that this novel material had good biocompatibility and biological safety. The wear performance of ULWPE and UHMWPE was evaluated in a pin-on-disc (POD) wear tester within two million cycles and a knee wear simulator within six million cycles. We found that the ULWPE was higher abrasion resistance than the UHMWPE, the wear rate of ULWPE by POD test and knee wear simulator was 0.4 mg/10cycles and (16.9 ± 1.8)mg/10cycles respectively, while that of UHMWPE was 1.8 mg/10cycles and (24.6 ± 2.4)mg/10cycles. The morphology of wear debris is also an important factor to evaluate artificial joint materials, this study showed that the ULWPE wear debris gotten from the simulator had various different shapes, including spherical, block, tear, etc. The morphology of worn surface and wear debris analysis showed that wear mechanisms of ULWPE were adhesion wear, abrasive wear and fatigue wear and other wear forms, which were consistent with that of UHMWPE. Thus we conclude that ULWPE is expected to be a lifetime implantation of artificial joint.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2018.03.009DOI Listing

Publication Analysis

Top Keywords

wear debris
16
wear
15
artificial joint
12
study biocompatibility
8
debris characterization
8
ultra-low-wear polyethylene
8
joint materials
8
ulwpe
8
knee wear
8
wear simulator
8

Similar Publications

This study investigates the effect of contact force on the friction and wear behavior of copper-graphene (Cu-CuG) nanocomposites against AISI 52,100 steel. Pin-on-disk dry sliding wear tests were conducted under normal forces of 10 and 30 N, with a sliding distance of 1000 m and a linear speed of 0.1 m/s.

View Article and Find Full Text PDF

Cobalt-chromium-molybdenum (Co-Cr-Mo) femoral components are widely used in total knee arthroplasty (TKA) due to their mechanical strength and wear performance. However, concerns regarding corrosion, metal ion release, and hypersensitivity have prompted the development of alternative materials, including nitrided titanium-aluminum-vanadium (nTi-6Al-4V). This study aimed to compare the simulated wear performance of Co-Cr-Mo and nTi-6Al-4V femoral components when articulated against conventional polyethylene articular surface bearings and evaluate the fatigue performance of nTi-6Al-4V components.

View Article and Find Full Text PDF

In this study, dry sliding wear tests were carried out on Er, Zr-microalloyed Al-Zn-Mg alloys with different Zn/Mg ratios under 30-70 N loads. The effects of the Zn/Mg content ratio and Er microalloying on the friction coefficient, wear volume loss, worn surface, and wear debris during the friction process of Al-Zn-Mg alloys were analyzed. At the load of 30 N, abrasive wear, fatigue wear, and adhesive wear were synergistically involved.

View Article and Find Full Text PDF

Background: The Porous Coated Motion (PCM) is a ball-and-socket cervical disc replacement with excellent reported short-term clinical outcome. However, longer-term studies identified migration as a common cause of implant removal and the device was withdrawn from the market. Given these discrepancies, retrieval analyses are crucial to assess whether preclinical testing accurately predicts clinical performance.

View Article and Find Full Text PDF

Introduction: Adverse local tissue reactions (ALTRs) is a known complication post total hip arthroplasty (THA). ALTR is usually associated with cobalt chromium alloy joints with incidence rate of 36-61%. It has also been documented in mixed bearings such as metal on polyethylene.

View Article and Find Full Text PDF