Article Abstract

The resolution and quantitative accuracy of PET are highly influenced by the reconstruction method. Penalized-likelihood estimation algorithms allow for fully convergent iterative reconstruction, generating a higher image contrast than ordered-subsets expectation maximization (OSEM) while limiting noise. In this study, a type of penalized reconstruction known as block-sequential regularized expectation maximization (BSREM) was compared with time-of-flight OSEM (TOF OSEM). Various strengths of noise penalization factor β were tested along with various acquisition durations and transaxial fields of view (FOVs) with the aim of evaluating the performance and clinical use of BSREM for F-FDG PET/CT, both quantitatively and in a qualitative visual evaluation. Eleven clinical whole-body F-FDG PET/CT examinations acquired on a digital TOF PET/CT scanner were included. The data were reconstructed using BSREM with point-spread function recovery and β-factors of 133, 267, 400, and 533-and using TOF OSEM with point-spread function-for various acquisition times per bed position and various FOVs. Noise level, signal-to-noise ratio (SNR), signal-to-background ratio (SBR), and SUV were analyzed. A masked evaluation of visual image quality, rating several aspects, was performed by 2 nuclear medicine physicians to complement the analysis. The lowest levels of noise were reached with the highest β-factor, resulting in the highest SNR, which in turn resulted in the lowest SBR. A β-factor of 400 gave noise equivalent to TOF OSEM but produced a significant increase in SUV (11%), SNR (22%), and SBR (12%). BSREM with a β-factor of 533 at a decreased acquisition duration (2 min/bed position) was comparable to TOF OSEM at a full acquisition duration (3 min/bed position). Reconstructed FOV had an impact on BSREM outcome measures; SNR increased and SBR decreased when FOV was shifted from 70 to 50 cm. The evaluation of visual image quality resulted in similar scores for reconstructions, although a β-factor of 400 obtained the highest mean whereas a β-factor of 267 was ranked best in overall image quality, contrast, sharpness, and tumor detectability. In comparison with TOF OSEM, penalized BSREM reconstruction resulted in an increased tumor SUV and an improved SNR and SBR at a matched level of noise. BSREM allowed for a shorter acquisition than TOF OSEM, with equal image quality.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnumed.117.200790DOI Listing

Publication Analysis

Top Keywords

tof osem
24
image quality
16
penalized-likelihood estimation
8
pet/ct scanner
8
expectation maximization
8
osem
8
f-fdg pet/ct
8
evaluation visual
8
visual image
8
highest β-factor
8

Similar Publications

The Omni Legend (GE Healthcare), equipped with a digital bismuth germanium oxide PET/CT system, has been recently developed. However, the performance of the Omni Legend without a time-of-flight (TOF) system for F-fluciclovine imaging is still unclear. Therefore, this study evaluated the image quality of the Omni Legend according to the Japanese brain tumor phantom test (JBT) criteria, and assessed its potential use for F-fluciclovine imaging.

View Article and Find Full Text PDF

 Focusing on the heterogeneity within cancer lesions and revealing cancer lesions with a high signal-to-noise ratio will help improve the quality of positron emission tomography (PET) images. This study aimed to understand how glucose metabolic activity can be shown with less statistical noise using a quality assessment phantom modeled after cancer lesions with a two-layer structure and a Clear adaptive Low-noise Method (CaLM) filter.  A National Electrical Manufacturers Association phantom with two spheres with a two-layer structure filled with 2-deoxy-2[ F]fluoro-D-glucose (inner and outer diameters of the spheres were 13/22 and 22/37 mm, respectively; radioactivity ratio of the background [BG] to outer sphere layer was 1:4; and BG-to-inner sphere layer ratios were 1:1, 1:2, and 1:3) was evaluated.

View Article and Find Full Text PDF

Background: The digital-BGO PET/CT system, Omni Legend 32, incorporates modified block sequential regularized expectation maximization (BSREM) image reconstruction and a deep learning-based time-of-flight (TOF)-like image quality enhancement process called Precision DL (PDL). The present study aimed to define the fundamental characteristics of PDL using phantom and clinical images.

Methods: A NEMA IEC body phantom was scanned using the Omni Legend 32 PET/CT system.

View Article and Find Full Text PDF

Using National Electrical Manufacturers Association (NEMA) phantom, the behavior of four distinct Positron Emission Tomography/Computed Tomography (PET/CT) reconstruction algorithms was investigated. These reconstruction algorithms were (Ordered Subset Expectation Maximization (OSEM), OSEM+ (Point Spread Function) PSF, OSEM + Time of Flight (TOF), and OSEM + TOF + PSF), and the focus was on sphere sizes and SBRs using recovery coefficients as a quantitation method. The obtained results demonstrated the significant effect of TOF on Gibbs artifact and Partial Volume Effect (PVE) at various Sphere-to-Background Ratios (SBRs).

View Article and Find Full Text PDF

Objectives: We investigated image quality and standardized uptake values (SUVs) for different lesion sizes using clinical data generated by F-FDG-prone breast silicon photomultiplier (SiPM)-based positron emission tomography/computed tomography (PET/CT).

Methods: We evaluated the effect of point-spread function (PSF) modeling and Gaussian filtering (Gau) and determined the optimal reconstruction conditions. We compared the signal-to-noise ratio (SNR), contrast, %coefficient of variation (%CV), SUV, and Likert scale score between ordered-subset expectation maximization (OSEM) time-of-flight (TOF) and OSEM+TOF+PSF in phantom and clinical studies.

View Article and Find Full Text PDF