A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

G-EYE advanced colonoscopy for improved polyp detection rates - a randomized tandem pilot study with different endoscopists. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Aims:  The most commonly missed polyps in colonoscopy are those located behind haustral folds. The G-EYE system is a standard colonoscope consisting of re-processable balloon at its distal tip. The G-EYE balloon improves the detection of polyps by straightening the haustral folds. In our back-to-back tandem study, we aimed to determine whether and to what extent the G-EYE system could reduce adenoma miss rates in screening colonoscopy.

Methods:  Patients referred to colonoscopy were randomized into 2 groups. Group A underwent a standard colonoscopy (SC) followed by balloon colonoscopy (BC), and Group B underwent BC followed by SC. In this randomized tandem study, the investigator's level of training and the endoscopists themselves were changed after each withdrawal. Each endoscopist was blinded to the results of the first withdrawal.

Results:  Fifty-eight patients were enrolled and randomized into 2 groups with similar baseline characteristics. Nine patients were excluded from the study. Twenty-five patients underwent SC followed by BC while 24 underwent BC followed by SC. The adenoma miss rate for SC was 41 %, with an additional detection rate of 69 % for BC (ratio 1.69). The overall miss rate for polyps was 60 % for SC, with an additional detection rate of 150 % for BC (ratio 2.5). Experienced investigators who used BC were able to identify an additional 7 polyps while inexperienced investigators.

Conclusions:  Although our results could not clearly confirm that BC improves adenoma detection, the investigator's experience appears to be a major determinant of the adenoma detection rate.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0043-124089DOI Listing

Publication Analysis

Top Keywords

detection rate
12
randomized tandem
8
haustral folds
8
g-eye system
8
tandem study
8
randomized groups
8
group underwent
8
additional detection
8
adenoma detection
8
detection
6

Similar Publications