Article Abstract

Background: Abnormal aortic flow patterns in bicuspid aortic valve disease (BAV) may be partly responsible for the associated aortic dilation. Aortic valve replacement (AVR) may normalize flow patterns and potentially slow the concomitant aortic dilation. We therefore sought to examine differences in flow patterns post AVR.

Methods: Ninety participants underwent 4D flow cardiovascular magnetic resonance: 30 BAV patients with prior AVR (11 mechanical, 10 bioprosthetic, 9 Ross procedure), 30 BAV patients with a native aortic valve and 30 healthy subjects.

Results: The majority of subjects with mechanical AVR or Ross showed normal flow pattern (73% and 67% respectively) with near normal rotational flow values (7.2 ± 3.9 and 10.6 ± 10.5 mm/ms respectively vs 3.8 ± 3.1 mm/s for healthy subjects; both p > 0.05); and reduced in-plane wall shear stress (0.19 ± 0.13 N/m for mechanical AVR vs. 0.40 ± 0.28 N/m for native BAV, p < 0.05). In contrast, all subjects with a bioprosthetic AVR had abnormal flow patterns (mainly marked right-handed helical flow), with comparable rotational flow values to native BAV (20.7 ± 8.8 mm/ms and 26.6 ± 16.6 mm/ms respectively, p > 0.05), and a similar pattern for wall shear stress. Data before and after AVR (n = 16) supported these findings: mechanical AVR showed a significant reduction in rotational flow (30.4 ± 16.3 → 7.3 ± 4.1 mm/ms; p < 0.05) and in-plane wall shear stress (0.47 ± 0.20 → 0.20 ± 0.13 N/m; p < 0.05), whereas these parameters remained similar in the bioprosthetic AVR group.

Conclusions: Abnormal flow patterns in BAV disease tend to normalize after mechanical AVR or Ross procedure, in contrast to the remnant abnormal flow pattern after bioprosthetic AVR. This may in part explain different aortic growth rates post AVR in BAV observed in the literature, but requires confirmation in a prospective study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5804071PMC
http://dx.doi.org/10.1186/s12968-018-0431-5DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
flow patterns
12
mechanical avr
12
bicuspid aortic
8
valve disease
8
cardiovascular magnetic
8
magnetic resonance
8
aortic dilation
8
bav patients
8
rotational flow
8

Similar Publications

Aortic and mitral valve repair in a child with rheumatic heart disease.

Multimed Man Cardiothorac Surg

September 2025

Department of Cardiothoracic Surgery, Royal Children’s Hospital, Melbourne, Australia

The patient had rheumatic heart disease, which resulted in severe aortic and mitral valve regurgitation. Repair of both valves was performed at 9 years of age. During surgery, the retracted aortic valve cusps required extension with bovine pericardial patches and suture reduction annuloplasty, and the mitral valve was repaired using a Cosgrove-Edwards (Edwards Lifesciences LLC, Irvine, CA) annuloplasty band.

View Article and Find Full Text PDF

Objective: Endovascular treatment of cerebrovascular diseases can be challenging in patients with difficult access routes. We describe a turn-over technique using a balloon guiding catheter (BGC) via the transfemoral approach to perform neuroendovascular treatment.

Case Presentation: An 80-year-old female with a recurrent right middle cerebral artery (MCA) aneurysm after coil embolization underwent successful stent-assisted coiling via the transfemoral approach.

View Article and Find Full Text PDF

Infective endocarditis is a potentially fatal condition that can present with non-specific symptoms and rare hematologic manifestations, posing significant diagnostic challenges. We report a compelling case of a 67-year-old male with a history of type 2 diabetes, hypertension, and hyperlipidemia who sought medical attention for a five-month history of progressive iron deficiency anemia, accompanied by weight loss, fatigue, and vague constitutional symptoms. Initial extensive workup, including computed tomography of the thorax, abdomen, and pelvis, gastroscopy, colonoscopy, and transthoracic echocardiography, failed to identify an underlying cause.

View Article and Find Full Text PDF