Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model.

Strategies Trauma Limb Reconstr

Department of Trauma and Orthopaedics, Leeds General Infirmary, Great George Street, Leeds, UK.

Published: August 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

No entirely reliable method exists for assessing union during Ilizarov treatment. Premature removal results in potential treatment failure; hence, alternative methods warrant investigation. Wire deflection might provide an indication of fracture site deformation on weight bearing, indicating progress towards union. This study aimed to test a method for assessing wire deflection within an Ilizarov frame. (1) To assess the repeatability of our novel measurement method in measuring wire deflection within an Ilizarov frame in vitro. (2) To compare the amount of wire deflection in an unstable model with that in an intact bone model. (3) To assess accuracy of this method by comparing wire deflection measured with overall machine extension. Tests were performed on clinical grade-tensioned fine wire 4-ring Ilizarov constructs stabilising a simulated fracture, with and without an unstable defect. Models were sequentially loaded to 700 N using an Instron testing machine. A digital depth gauge attached to the superior ring measured relative wire displacement at the ring closest to the fracture. Tests were repeated 3 times. (1) Both unstable and stable bone models produced highly repeatable load deformation curves (R = 0.98 and 0.99). (2) In the unstable model, wires tensioned at 882 and 1274 N produced mean maximum deflections of 2.41 and 2.69 mm compared with 0.05 and 0.04 mm in the intact bone model (significant p < 0.0001). (3) Wire deflection and machine extension results were strongly correlated (r = 0.99). A measurable difference in wire deflection between stable and unstable situations exists using this method which appears accurate and repeatable, with clear correlation between displacement and load and displacement and machine extension. This approach might be clinically applicable, and further clinical testing is required.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6042221PMC
http://dx.doi.org/10.1007/s11751-018-0306-1DOI Listing

Publication Analysis

Top Keywords

wire deflection
24
union ilizarov
8
ilizarov constructs
8
deflection ilizarov
8
ilizarov frame
8
unstable model
8
intact bone
8
bone model
8
wire
7
deflection
6

Similar Publications

Model-based Parameter Selection for a Steerable Continuum Robot - Applications to Bronchoalveolar Lavage (BAL).

IEEE Robot Autom Lett

January 2025

Medical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA.

Bronchoalveolar lavage (BAL) is a minimally invasive procedure for diagnosing lung infections and diseases. However, navigating tortuous lung anatomy to the distal branches of the bronchoalveolar tree for adequate sampling using BAL remains challenging. Continuum robots have been used to improve the navigation of guidewires, catheters, and endoscopes and could be applied to the BAL procedure as well.

View Article and Find Full Text PDF

This study systematically evaluates the influence of copper (Cu) addition in gas-shielded solid wires on the microstructure and cryogenic toughness of X80 pipeline steel welds. Welds were fabricated using solid wires with varying Cu contents (0.13-0.

View Article and Find Full Text PDF

Background/purpose: Fixed lingual retainers (FLRs) often experience structural instability, including poor adaptation, and the untwisting of spiral wires, which can lead to unwanted tooth movement. Digital workflows have enhanced the appliance's accuracy. This study evaluated the water sorption (W), water solubility (W), staining resistance, and flexural performance of three-dimensionally printed resin (3DR) to determine its optimal design for FLRs.

View Article and Find Full Text PDF

Background: The Drivewire 24 (DW24) is a newly FDA-cleared 0.024 inch steerable guidewire. Its proximally controlled deflectable tip allows for intravascular steering to facilitate selective navigation of diagnostic or therapeutic catheters.

View Article and Find Full Text PDF

Comparison of two clamping mechanisms for Kirschner wires in Ilizarov fixator and Taylor Spatial Frame.

Injury

August 2025

Department of Mechanical and Aerospace Engineering, University of Manchester, Manchester, UK. Electronic address:

The purpose of the study was to examine and compare the tensile characteristics of 1.8 mm smooth Kirschner wires (K-wires) fixed with four different clamping mechanisms:Ilizarov and Taylor Spatial Frame (TSF) are two widely used types of external fixation devices, in both of which fine K-wires are used as transosseous elements. The K-wires are pretensioned and fixed to the rings using specialised fixation bolts.

View Article and Find Full Text PDF