Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

An exceptional property of photo-acoustic spectroscopy is the zero-background in wavelength modulation configuration while the signal varies linearly as a function of absorbed laser power. Here, we make use of this property by combining a highly sensitive cantilever-enhanced photo-acoustic detector, a particularly stable high-power narrow-linewidth mid-infrared continuous-wave optical parametric oscillator, and a strong absorption cross-section of hydrogen fluoride to demonstrate the ability of cantilever-enhanced photo-acoustic spectroscopy to reach sub-parts-per-trillion level sensitivity in trace gas detection. The high stability of the experimental setup allows long averaging times. A noise equivalent concentration of 650 parts-per-quadrillion is reached in 32 minutes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5789827PMC
http://dx.doi.org/10.1038/s41598-018-20087-9DOI Listing

Publication Analysis

Top Keywords

cantilever-enhanced photo-acoustic
12
photo-acoustic spectroscopy
12
sub-parts-per-trillion level
8
level sensitivity
8
sensitivity trace
8
trace gas
8
gas detection
8
detection cantilever-enhanced
4
photo-acoustic
4
spectroscopy exceptional
4

Similar Publications

We have improved the sensitivity of a state-of-the-art cantilever-enhanced photo-acoustic trace gas sensor by combining it with an optical power build-up cavity. The build-up cavity enhances the photo-acoustic signal by a factor of ∼100, resulting in an exceptionally good normalised noise equivalent absorption (NNEA) value of 1.75 × 10-12 W cm-1 Hz-1/2.

View Article and Find Full Text PDF

An exceptional property of photo-acoustic spectroscopy is the zero-background in wavelength modulation configuration while the signal varies linearly as a function of absorbed laser power. Here, we make use of this property by combining a highly sensitive cantilever-enhanced photo-acoustic detector, a particularly stable high-power narrow-linewidth mid-infrared continuous-wave optical parametric oscillator, and a strong absorption cross-section of hydrogen fluoride to demonstrate the ability of cantilever-enhanced photo-acoustic spectroscopy to reach sub-parts-per-trillion level sensitivity in trace gas detection. The high stability of the experimental setup allows long averaging times.

View Article and Find Full Text PDF

We present a simple and highly sensitive cantilever-enhanced photo-acoustic sensor for detection of nitrogen dioxide. A noise equivalent detection limit of 50 parts-per-trillion in 1 s is demonstrated. The limit was reached with an average optical power of 4.

View Article and Find Full Text PDF