An exceptional property of photo-acoustic spectroscopy is the zero-background in wavelength modulation configuration while the signal varies linearly as a function of absorbed laser power. Here, we make use of this property by combining a highly sensitive cantilever-enhanced photo-acoustic detector, a particularly stable high-power narrow-linewidth mid-infrared continuous-wave optical parametric oscillator, and a strong absorption cross-section of hydrogen fluoride to demonstrate the ability of cantilever-enhanced photo-acoustic spectroscopy to reach sub-parts-per-trillion level sensitivity in trace gas detection. The high stability of the experimental setup allows long averaging times. A noise equivalent concentration of 650 parts-per-quadrillion is reached in 32 minutes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5789827 | PMC |
http://dx.doi.org/10.1038/s41598-018-20087-9 | DOI Listing |
Analyst
March 2019
Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014, Helsinki, Finland.
We have improved the sensitivity of a state-of-the-art cantilever-enhanced photo-acoustic trace gas sensor by combining it with an optical power build-up cavity. The build-up cavity enhances the photo-acoustic signal by a factor of ∼100, resulting in an exceptionally good normalised noise equivalent absorption (NNEA) value of 1.75 × 10-12 W cm-1 Hz-1/2.
View Article and Find Full Text PDFSci Rep
January 2018
Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014, Helsinki, Finland.
An exceptional property of photo-acoustic spectroscopy is the zero-background in wavelength modulation configuration while the signal varies linearly as a function of absorbed laser power. Here, we make use of this property by combining a highly sensitive cantilever-enhanced photo-acoustic detector, a particularly stable high-power narrow-linewidth mid-infrared continuous-wave optical parametric oscillator, and a strong absorption cross-section of hydrogen fluoride to demonstrate the ability of cantilever-enhanced photo-acoustic spectroscopy to reach sub-parts-per-trillion level sensitivity in trace gas detection. The high stability of the experimental setup allows long averaging times.
View Article and Find Full Text PDFWe present a simple and highly sensitive cantilever-enhanced photo-acoustic sensor for detection of nitrogen dioxide. A noise equivalent detection limit of 50 parts-per-trillion in 1 s is demonstrated. The limit was reached with an average optical power of 4.
View Article and Find Full Text PDF