A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Does advancement in stapling technology with triple-row and enhanced staple configurations confer additional safety? A matched comparison of 340 stapled ileocolic anastomoses. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Over the past few decades, studies have focused on the safety of stapled anastomosis, especially when compared to that of the handsewn technique. However, studies on the improvement of stapling technology are limited. This study aimed to investigate whether linear triple-row staples (tri-staples) had any advantage over double-row staples.

Methods: This is a retrospective review of all cases of functional end-to-end anastomoses with linear staplers performed at two centers between 2005 and 2015. Data were retrieved from a prospectively maintained database. Cases of anastomoses performed with double-row (DS) and triple-row (TS) staples were matched according to propensity scores. The rates of anastomotic leakage, bleeding, reoperation, and 30-day mortality were compared.

Results: Functional end-to-end ileocolic anastomoses were performed in 563 consecutive patients during the study period. Double- and triple-row stapling devices were used in 389 and 174 anastomoses, respectively. With propensity score matching, 170 cases were chosen from each group. Both groups showed comparable baseline characteristics. The anastomotic leakage, anastomotic bleeding, and intra-abdominal collection rates were 2.4 and 0% (p = 0.123), 1.2 and 0% (p = 0.499), and 3.5 and 1.2% (p = 0.283) for DS and TS, respectively. The reoperation and 30-day mortality rates were 5.9 and 1.8% (p = 0.048) and 0.6 and 1.2% (p = 1.000) for DS and TS, respectively. The median lengths of stay were 5 and 6 days (p = 0.072) for DS and TS, respectively.

Conclusion: Anastomoses with triple-row staples tended to have a lower morbidity rate, but a significant advantage over double-row staples was not demonstrated in this study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-018-6027-1DOI Listing

Publication Analysis

Top Keywords

triple-row staples
12
stapling technology
8
ileocolic anastomoses
8
advantage double-row
8
functional end-to-end
8
anastomoses performed
8
anastomotic leakage
8
reoperation 30-day
8
30-day mortality
8
anastomoses
6

Similar Publications