A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Use of beta subunit of human chorionic gonadotropin assay as a diagnostic tool for prelabor rupture of membranes. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: The study aimed at assessment of the accuracy of the β-hCG test in vaginal washing fluid for diagnosis of prelabor rupture of membranes (PROM).

Patients And Methods: Two groups of pregnant women from 17 to 38 weeks of gestation were recruited. The first group (PROM group) included 50 pregnant women with unequivocal PROM. The other group included 50 pregnant women with intact membranes. A sterile speculum examination was performed. If less than 5 cc was collected or no fluid found, 10 cc sterile saline was sprinkled on the vaginal wall and 5 cc were recollected in a sterile syringe. Two drops of collected fluid were used for qualitative testing of β-hCG. The remaining fluid was used for quantitative assessment of β-hCG.

Results: The quantitative β-hCG test results were significantly higher in PROM group (median and range: 138.5 (23-475) versus 13 (1-55); the difference in medians and 95% CI: 105 (91-166); p value: <.001). The qualitative β-hCG test was positive in 42/50 (84%) of the PROM group, while it was negative in 50/50 (100%) of the intact membranes group. Areas under receiver operating characteristics (AUC) for both the quantitative and qualitative β-hCG tests were high (0.97, 95% CI: 0.91-0.99, p value: <.001 and .92, 95% CI: 0.84-0.96, p value: <.001, respectively). The suggested cut-off of β-hCG for the quantitative test was 32 mIU/ml. The sensitivity of quantitative and qualitative tests are: 94, 95% CI: 83.5-98.7% and 84, 95% CI: 70.9-92.8%, respectively. The specificity of quantitative and qualitative tests are: 94, 95% CI: 83.5-98.7% and 100, 95% CI: 92.9-100%, respectively.

Conclusion: β-hCG test (either quantitative or qualitative) in vaginal washing fluid can be used in the diagnosis of PROM in both preterm and term cases.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14767058.2017.1422712DOI Listing