98%
921
2 minutes
20
Dot-grid images are usually captured for grid strain analysis during sheet metal forming. Due to the strong reflective characteristic of the metallic surfaces, the recorded dot-grid images often have poor quality, low positioning accuracy, and low recognition rate. Therefore, an exposure-fusion-based dot-grid image acquisition and recognition approach is proposed. First, multiple dot-grid images are captured at different exposure levels. Subsequently, the recorded multi-exposure dot-grid images are fused into a new high-quality dot-grid image based on exposure fusion technology. Finally, a dot-grid image recognition procedure is developed to detect the dot-grids in the new dot-grid image. Both synthetic and real dot-grid images were tested to verify the performance of the novel approach. When synthetic dot-grid images were tested, the maximum positioning error was up to 6.044 pixels if they were recognized in the traditional way, whereas the maximum positioning error was reduced to 0.132 pixels if the novel approach was adopted. When real dot-grid images were tested, the lowest recognition rate is only 50.52% if they were recognized in the traditional way. Nevertheless, the recognition rate can reach about 91% if the novel approach was employed. These experimental results show the superiorities of the novel approach.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.56.009706 | DOI Listing |
Sci Rep
January 2025
Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA.
Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.
View Article and Find Full Text PDFMed Phys
May 2023
Wellcome EPSRC Centre for Interventional and Surgical Sciences, UCL, London, UK.
Background: Accurate camera and hand-eye calibration are essential to ensure high-quality results in image-guided surgery applications. The process must also be able to be undertaken by a nonexpert user in a surgical setting.
Purpose: This work seeks to identify a suitable method for tracked stereo laparoscope calibration within theater.
Aesthet Surg J
October 2018
Division of Plastic Surgery, Emory University.
Background: Force modulating tissue bridges (FMTB) represent a new class of combined wound closure and scar reduction device designed to optimize the tension milieu of the healing wound.
Objectives: Engineering analysis and testing in both intact skin and incisional models was undertaken to assess changes in tissue tension associated with device placement and compare to standard suture closure.
Methods: Nonlinear, large deformation finite element analyses (FEA) were performed to compare the strains applied to tissues with sutures and FMTB.
Dot-grid images are usually captured for grid strain analysis during sheet metal forming. Due to the strong reflective characteristic of the metallic surfaces, the recorded dot-grid images often have poor quality, low positioning accuracy, and low recognition rate. Therefore, an exposure-fusion-based dot-grid image acquisition and recognition approach is proposed.
View Article and Find Full Text PDFWaste Manag
June 2015
School of Energy, Environment and Agrifood, Cranfield University, Cranfield, Bedfordshire MK43 0AL, UK. Electronic address:
An experimental study was completed using a previously developed and innovative image analysis approach, which has been applied here to shredded waste materials representative of waste-derived fuels. Waste components were collected from source-segregated recycling containers and shredded to <150 mm. These materials were then used to produce 3× samples of different composition.
View Article and Find Full Text PDF