98%
921
2 minutes
20
Aquatic organisms are usually exposed to a mixture of xenobiotics that may exert a large effect even in low concentrations, and when information is obtained exclusively from chemical analyses the prediction of the deleterious effects is potentially hindered. Therefore, the application of complementary monitoring methods is a priority. Here, in addition to chemical analyses, an active biomonitoring study using multiple biomarker responses in Nile tilapia Oreochromis niloticus was conducted to assess the effects of a contamination gradient along four reservoirs in Iguaçu River. Chemical analysis in the muscle showed high levels of metals in fish from the reservoir closest to an industrialized and environmentally degraded area, however fish exposed to all studied reservoirs showed hepatic alterations (necrosis and inflammatory processes). Also, significant variations of biochemical biomarkers were observed with no clear indication of contamination gradient, since an indicative of higher impact was found in an intermediary reservoir, including high concentrations of biliary polycyclic aromatic hydrocarbons (PAHs). However, nuclear morphological alterations (NMA) were less frequent at the same reservoir. Thus, the multi-biomarker approach allied to active biomonitoring is a practical and important tool to assess deleterious effects of contamination in freshwater, providing data for monitoring and conservation protocols.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ecoenv.2017.11.036 | DOI Listing |
J Enzyme Inhib Med Chem
December 2025
School of Life Sciences, Jinggangshan University, Ji'an, China.
Current antithrombotic therapies face dual constraints of bleeding complications and monitoring requirements. Although natural hirudin provides targeted thrombin inhibition, its clinical adoption is hindered by sourcing limitations. This study developed a recombinant hirudin variant HMg (rHMg) with enhanced anticoagulant activity through genetic engineering and established cost-effective large-scale production methods.
View Article and Find Full Text PDFAnal Chim Acta
November 2025
The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, PR China; Center of Self-Propelled Nanotechnologies, Suzhou Industrial Park Institute of Services Outsourcing, Suzhou, 215123, PR China
Background: Of the mycotoxins, aflatoxin is the most significant. The detection of aflatoxin B1 (AFB1) is crucial for ensuring food safety, as this highly carcinogenic toxin readily contaminates crops such as grains and nuts, and timely detection can effectively prevent associated health risks. The selection of luminophores is of paramount importance in the detection of ECL (electrochemiluminescence).
View Article and Find Full Text PDFAnal Chim Acta
November 2025
Institute of Materials Science, Vietnam Academy of Science and Technology, Hanoi, 10000, Viet Nam. Electronic address:
Background: Recent advancements in cancer therapeutics have catalyzed the development of noninvasive treatment modalities, including the utilization of fluorescent chemotherapeutic agents. These agents offer dual functionality, enabling targeted drug delivery, real-time tumor imaging, and personalized therapy monitoring. Such capabilities are instrumental in the progression toward more precise and effective cancer interventions.
View Article and Find Full Text PDFEnviron Res
September 2025
Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 10608, Taiwan; High-value Biomaterials Research and Commercialization Center, National Taipei University of Technology, Taipei 10608, Taiwan. Electronic address:
The persistent presence of the pharmaceutical pollutant nilutamide (NLT) in environmental and biological systems poses a serious threat to ecosystems and human health, necessitating efficient and sustainable detection strategies. In this study, we present a nanoengineered SrWO@MXene electrocatalyst as a high-performance platform for electrochemical sensing. The hybrid material seamlessly integrates the catalytic activity and electrochemical stability of SrWO with the exceptional conductivity and tunable surface chemistry of MXenes, resulting in a synergistic architecture optimized for rapid and selective NLT detection.
View Article and Find Full Text PDFTalanta
August 2025
Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Departamento de Química Biológica, Junín 956, Buenos Aires, Argentina; Laboratorio de Biofísica Molecular, Instituto de Química y Fisicoquímica Biológicas, UBA - CONICET, Junín 956, Buenos Aires, Argentina. Electronic address:
The quantification of orthophosphate is essential for applications like water quality assessment, soil fertility analysis, metabolic monitoring and enzyme activity evaluation. Chemical quantification methods include the reaction between orthophosphate and molybdate under acidic conditions to form 12-molybdophosphoric acid units, which auto-assembles forming nanometer size particles. The adsorption of malachite green to these nanoparticles allows their spectrophotometric detection constituting one of the most widely used methods to quantify phosphate.
View Article and Find Full Text PDF