Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Unlabelled: The challenges of using physical activity data from accelerometers have been compounded with the recent focus on wrist-worn monitors and raw acceleration (as opposed to activity counts).
Purpose: This study developed and systematically evaluated a suite of new accelerometer processing models for youth.
Methods: Four adaptations of the Sojourn method were developed using data from a laboratory-based experiment in which youth (N = 54) performed structured activity routines. The adaptations corresponded to all possible pairings of hip or wrist attachment with activity counts (AC) or raw acceleration (RA), and they estimated time in sedentary behavior, light activity, and moderate-to-vigorous physical activity. Criterion validity was assessed using direct observation in an independent free-living sample (N = 27). Monitors were worn on both wrists to evaluate the effect of handedness on accuracy, and status quo methods for each configuration were also evaluated as benchmarks for comparison. Tests of classification accuracy (percent accuracy, κ statistics, and sensitivity and specificity) were used to summarize utility.
Results: In the development sample, percent accuracy ranged from 68.5% (wrist-worn AC, κ = 0.42) to 71.6% (hip-worn RA, κ = 0.50). Accuracy was lower in the free-living evaluation, with values ranging from 49.3% (hip-worn RA, κ = 0.25) to 56.7% (hip-worn AC, κ = 0.36). Collectively, the suite predicted moderate-to-vigorous physical activity well, with the models averaging 96.5% sensitivity and 67.5% specificity. However, in terms of overall accuracy, the new models performed similarly to the status quo methods. There were no meaningful differences in performance at either wrist.
Conclusions: The new models offered minimal improvements over existing methods, but a major advantage is that further tuning of the models is possible with continued research.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1249/MSS.0000000000001486 | DOI Listing |