A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Surface electromyography for analysis of heart rate variability in preterm infants. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Characterizing heart rate variability (HRV) in neonates has gained increased attention and is helpful in quantifying maturation and risk of sepsis in preterm infants. Raw data used to derive HRV in a clinical setting commonly contain noise from motion artifacts. Thoracic surface electromyography (sEMG) potentially allows for pre-emptive removal of motion artifacts and subsequent detection of interbeat interval (IBI) of heart rate to calculate HRV. We tested the feasibility of sEMG in preterm infants to exclude noisy raw data and to derive IBI for HRV analysis. We hypothesized that a stepwise quality control algorithm can identify motion artifacts which influence IBI values, their distribution in the time domain, and outcomes of nonlinear time series analysis.

Approach: This is a prospective observational study in preterm infants  <6 days of age. We used 100 sEMG measurements from 24 infants to develop a semi-automatic quality control algorithm including synchronized video recording, threshold-based sEMG envelope curve, optimized QRS-complex detection, and final targeted visual inspection of raw data.

Main Results: Analysis of HRV from sEMG data in preterm infants is feasible. A stepwise algorithm to exclude motion artifacts and improve QRS detection significantly influenced data quality (34% of raw data excluded), distribution of IBI values in the time domain, and nonlinear time series analysis. The majority of unsuitable data (94%) were excluded by automated steps of the algorithm.

Significance: Thoracic sEMG is a promising method to assess motion artifacts and calculate HRV in preterm neonates.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6579/aa996aDOI Listing

Publication Analysis

Top Keywords

heart rate
12
preterm infants
12
motion artifacts
12
surface electromyography
8
rate variability
8
raw data
8
data derive
8
electromyography analysis
4
analysis heart
4
preterm
4

Similar Publications