Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The ability to use indirect cyanmethemoglobin method using 20 µl of dried blood spots (DBSs) on filter paper for the analysis of haemoglobin (Hb) levels could be an important diagnostic tool for areas that have limited access to laboratory facilities. We assessed the validity of a method for Hb estimation in which a single drop of whole blood was directly taken on the filter paper. We collected 124 DBSs containing 20 µl of blood (filter paper A) and single drop of whole blood (filter paper B) from subjects living in Nainital, Uttrakhand. Estimation of Hb was done by indirect cyanmethemoglobin method in both the filter papers. A correction factor for predicting value of Hb from DBSs of single drop of whole blood was established. The Bland-Altman plot suggested that the difference in Hb values obtained by the single drop of blood and 20 µl of DBSs was within the 1.5 SD limits, suggesting high validity of the correction factor. The estimation of Hb using single drop of whole blood on filter paper after applying the correction factor provides results similar to indirect cyanmethemoglobin method using 20 µl of blood. Hence, single drop of whole blood on filter paper can be used as an alternate method for estimation of Hb in large scale community surveys.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5640525PMC
http://dx.doi.org/10.1007/s12288-016-0766-8DOI Listing

Publication Analysis

Top Keywords

single drop
24
filter paper
16
indirect cyanmethemoglobin
12
cyanmethemoglobin method
12
drop blood
12
correction factor
12
dried blood
8
method 20 µl
8
method estimation
8
estimation single
8

Similar Publications

Archimedean spirals are architectural motifs that are found in nature. The facial asymmetry of amphiphilic molecules or macromolecules has been a key parameter in the preparation of these well-organized two-dimensional nanostructures in the laboratory. This facial asymmetry is also present in the helical grooves of chiral helical substituted poly(phenylacetylene)s (PPAs) and poly(diphenylacetylene)s (PDPAs), making them excellent candidates for self-assembly into 2D Archimedean nanospirals or nanotoroids.

View Article and Find Full Text PDF

Determination of alcohol concentration in a single drop blood obtained via fingertip using gas chromatography/mass spectrometry coupled with solid-phase microextraction.

Leg Med (Tokyo)

September 2025

Department of Analytical Chemistry, School of Pharmacy and Pharmaceutical Sciences, Hoshi University, 2-4-41, Ebara, Shinagawa-ku, Tokyo 142-8501, Japan.

This study investigated headspace solid-phase microextraction (HS-SPME)-gas chromatography (GS)/mass spectrometry as a low-complexity method for accurate measurement of blood alcohol concentration (BAC) changes in humans over time following alcohol consumption. The aim was to develop an analytical method that would require as small blood samples as possible-smaller than that required for the conventional method-thereby reducing the burden on the subject. Polyethylene glycol (PEG) was used as the fiber material for SPME, and a DB-WAX capillary column was used for GC.

View Article and Find Full Text PDF

The objective of this observational study was to describe the association between lag time from calving to first milking for colostrum harvest. Colostrum samples from primiparous and multiparous Holstein cows (n = 640) from a single herd milking approximately 5,200 cows 3 times daily in a 100-stall rotary parlor were used in this prospective cohort study. Calves were removed immediately after calving and not allowed to suckle their dam.

View Article and Find Full Text PDF

Introduction Stereotactic radiosurgery (SRS) is widely regarded as the standard of care after the resection of brain metastases in order to reduce local cavity recurrence risk. The objective of this study was to explore the reproducibility of published outcomes for patients receiving post-operative stereotactic radiosurgery (cavity SRS) in a National Health Service (NHS) setting for a non-selective series of patients. For our service, the median interval between surgery to cavity SRS (cSRS) is eight weeks, whereas similar timelines have been found to have a deleterious impact on survival in the published literature.

View Article and Find Full Text PDF

Background: Cardiac biomarkers are important components for diagnosing perioperative myocardial infarction (MI). Efforts to detect MI by biomarker-release only faced heavy criticism, because cardiac biomarker-release has also been observed in situations that are not always related to cell death (e.g.

View Article and Find Full Text PDF