A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Performance of rapid diagnostic tests for the detection of anti-HBs in various patient populations. | LitMetric

Performance of rapid diagnostic tests for the detection of anti-HBs in various patient populations.

J Clin Virol

National Reference Center for Viral Hepatitis B, C and D, Department of Virology, Hôpital Henri Mondor, Université Paris-Est, Créteil, France; INSERM U955, Créteil, France. Electronic address:

Published: November 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Rapid diagnostic tests (RDTs) represent an attractive alternative method to conventional diagnosis of hepatitis B virus (HBV) infection.

Objective: The aim of the present study was to evaluate the diagnostic performance of commercially available RDTs for the detection of anti-HBs in various patient populations.

Study Design: A total of 347 individuals, 198 positive and 149 negative for anti-HBs, were studied.

Results: The specificity of RDT detection of anti-HBs in serum was 98.0%, 96.0% and 97.3% with TOYO® HBsAb Test, QuickProfile™ HBsAb test and QuickProfile™ HBV-3 Panel test, respectively. The diagnostic sensitivity varied between 60.4% and 69.5%. The sensitivity of the three RDTs was markedly better when testing serum samples with an anti-HBs titer higher than 100IU/L, and reached 90% or more for an anti-HBs titer above 150IU/L.

Conclusions: This performance was disappointing because the assays were not sensitive enough to detect low antibody titers. Thus, these tests require further improvement before they can be widely used in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcv.2017.09.012DOI Listing

Publication Analysis

Top Keywords

detection anti-hbs
12
rapid diagnostic
8
diagnostic tests
8
anti-hbs patient
8
hbsab test
8
test quickprofile™
8
anti-hbs titer
8
anti-hbs
6
performance rapid
4
diagnostic
4

Similar Publications