Portable (handheld) clinical device for quantitative spectroscopy of skin, utilizing spatial frequency domain reflectance techniques.

Rev Sci Instrum

Beckman Laser Institute and Medical Clinic, University of California, Irvine, 1002 Health Sciences Road East, Irvine, California 92612, USA.

Published: September 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Spatial Frequency Domain Spectroscopy (SFDS) is a technique for quantifying in-vivo tissue optical properties. SFDS employs structured light patterns that are projected onto tissues using a spatial light modulator, such as a digital micromirror device. In combination with appropriate models of light propagation, this technique can be used to quantify tissue optical properties (absorption, μ, and scattering, μ', coefficients) and chromophore concentrations. Here we present a handheld implementation of an SFDS device that employs line (one dimensional) imaging. This instrument can measure 1088 spatial locations that span a 3 cm line as opposed to our original benchtop SFDS system that only collects a single 1 mm diameter spot. This imager, however, retains the spectral resolution (∼1 nm) and range (450-1000 nm) of our original benchtop SFDS device. In the context of homogeneous turbid media, we demonstrate that this new system matches the spectral response of our original system to within 1% across a typical range of spatial frequencies (0-0.35 mm). With the new form factor, the device has tremendously improved mobility and portability, allowing for greater ease of use in a clinical setting. A smaller size also enables access to different tissue locations, which increases the flexibility of the device. The design of this portable system not only enables SFDS to be used in clinical settings but also enables visualization of properties of layered tissues such as skin.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5589466PMC
http://dx.doi.org/10.1063/1.5001075DOI Listing

Publication Analysis

Top Keywords

spatial frequency
8
frequency domain
8
tissue optical
8
optical properties
8
sfds device
8
original benchtop
8
benchtop sfds
8
device
6
sfds
6
spatial
5

Similar Publications

Objective: Diffusion magnetic resonance imaging (dMRI) often suffers from low spatial and angular resolution due to inherent limitations in imaging hardware and system noise, adversely affecting the accurate estimation of microstructural parameters with fine anatomical details. Deep learning-based super-resolution techniques have shown promise in enhancing dMRI resolution without increasing acquisition time. However, most existing methods are confined to either spatial or angular super-resolution, disrupting the information exchange between the two domains and limiting their effectiveness in capturing detailed microstructural features.

View Article and Find Full Text PDF

Timely access to comprehensive , high-quality emergency obstetric and neonatal care can prevent maternal and neonatal mortality but remains challenging in Benin. We examine geographic accessibility to childbirth care (CBC) in Grand Nokoué, the largest conurbation in Benin. We gathered data on boundaries, health facilities, road network, elevation, land cover, relative wealth, urbanicity, and geo-traced travel speeds over 45 days during the rainy season.

View Article and Find Full Text PDF

Individual alpha frequency tACS modifies the detection of space-time optical illusion.

Exp Brain Res

September 2025

Siena Brain Investigation and Neuromodulation Lab (Si-BIN Lab), Department of Medicine, Surgery and Neuroscience, Neurology and Clinical Neurophysiology Section, University of Siena, Siena, Italy.

Postdiction is a perceptual phenomenon where the perception of an earlier stimulus is influenced by a later one. This effect is commonly studied using the 'rabbit illusion', in which temporally regular, but spatially irregular, stimuli are perceived as equidistant. While previous research has focused on short inter-stimulus intervals (100-200 ms), the role of longer intervals, which may engage late attentional processes, remains unexplored.

View Article and Find Full Text PDF

"Characterization of visual function parameters in relation to macular pigment optical density in a pediatric population".

Graefes Arch Clin Exp Ophthalmol

September 2025

Department of Physics of Condensed Matter, Optics Area. Vision Research Group (CIVIUS), University of Seville, Avenida de la Reina Mercedes s/n (41012), Seville, Spain.

Purpose: To analyze the relationship between various visual function parameters (refractive status, visual acuity and contrast sensitivity) and macular pigment optical density (MPOD) values, as well as dietary intake of lutein and zeaxanthin in a pediatric population.

Methods: Thirty-six healthy White pediatric patients participated in this cross-sectional study conducted at the Optometry Clinic (Faculty of Pharmacy, Seville, Spain). MPOD values were measured using the MPSII (Macular Pigment Screener II).

View Article and Find Full Text PDF

In this paper, a single-quartz-enhanced photoacoustic-photothermal dual spectroscopy sensor based on a spherical acoustic resonator (SAR) is reported for the first time. The dual spectroscopy of quartz-enhanced photoacoustic spectroscopy (QEPAS) and quartz-enhanced photothermal spectroscopy (QEPTS), utilizing a single quartz tuning fork (QTF), eliminates the frequency mismatch issue that occurs when multiple QTFs are used. The dual spectroscopy model was constructed using the finite element method, which provides numerical simulation support for subsequent experiments.

View Article and Find Full Text PDF