Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We describe a sequential windowed acquisition of all theoretical fragment ion mass spectra (SWATH-MS) based method for label-free, simultaneous, relative quantification of drug metabolism enzymes in human liver microsomes (HLM; n = 78). In-solution tryptic digestion was aided by a pressure cycling method, which allowed a 90 min incubation time, a significant reduction over classical protocols (12-18 h). Digested peptides were separated on an Acquity UHPLC Peptide BEH C18 column using a 60 min gradient method at a flow rate of 0.100 mL/min. The quadrupole-time-of-flight mass spectrometer (ESI-QTOFMS) was operated in positive electrospray ionization mode, and data were acquired by data-dependent acquisition (DDA) and SWATH-MS mode. A pooled HLM sample was used as a quality control to evaluate variability in digestion and quantification among different batches, and inter-batch %CV for various proteins was between 3.1 and 7.8%. Spectral library generated from the DDA data identified 1855 distinct proteins and 25 681 distinct peptides at a 1% global false discovery rate (FDR). SWATH data were queried and analyzed for 10 major cytochrome P450 (CYP) enzymes using Skyline, a targeted data extraction software. Further, correlation analysis was performed between functional activity, protein, and mRNA expression for ten CYP enzymes. Pearson correlation coefficient (r) between protein and activity for CYPs ranged from 0.314 (CYP2C19) to 0.767 (CYP2A6). A strong correlation was found between CYP3A4 and CYP3A5 abundance and activity determined using midazolam and testosterone (r > 0.600, p < 0.001). Protein-to-activity correlation was moderate (r > 0.400-0.600, p < 0.001) for CYP1A2, CYP2A6, CYP2B6, CYP2C9, and CYP2E1 and significant but poor (r < 0.400, p < 0.05) for CYP2C8, CYP2C19, and CYP2D6. The findings suggest the suitability of SWATH-MS based method as a valuable and relatively fast analytical technique for relative quantification of proteins in complex biological samples. We also show that protein abundance is a better surrogate than mRNA to predict the activity of CYP activity.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.jproteome.7b00505DOI Listing

Publication Analysis

Top Keywords

relative quantification
12
protein abundance
8
enzymes human
8
human liver
8
liver microsomes
8
swath-ms based
8
based method
8
cyp enzymes
8
activity
5
multiplex label-free
4

Similar Publications

Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.

View Article and Find Full Text PDF

On-site mercury analyser employing enclosed quartz cell cold vapour atomic absorption spectrometry and 3D printing techniques.

Talanta

September 2025

Department of Chemistry and Biotechnology, Faculty of Science and Technology, Kochi University, 2-5-1 Akebono-cho, Kochi City, Kochi, 780-8520, Japan. Electronic address:

The development of on-site Hg analysers is crucial for the rapid evaluation of Hg concentrations in environmental research. However, the fabrication of Hg analysers requires simplification of analytical procedures and device miniaturisation. Based on the above requirements, our research group previously investigated enclosed quartz cell cold vapour atomic absorption spectrometry (EQC-CV-AAS) as a base technique for an on-site Hg analyser.

View Article and Find Full Text PDF

The helical morphology of Type B aortic dissections (TBAD) represents a potentially important geometric biomarker that may influence dissection progression. While three-dimensional surface-based quantification methods provide accurate TBAD helicity assessment, their clinical adoption remains limited by significant processing time. We developed and validated a clinically practical centerline-based helicity quantification method using routine imaging software (TeraRecon) against an extensively validated surface-based method (SimVascular).

View Article and Find Full Text PDF

Purpose: Fat fraction (FF) quantification in individual muscles using quantitative MRI is of major importance for monitoring disease progression and assessing disease severity in neuromuscular diseases. Undersampling of MRI acquisitions is commonly used to reduce scanning time. The present paper introduces novel unrolled neural networks for the reconstruction of undersampled MRI acquisitions.

View Article and Find Full Text PDF

Polyester-coated stainless-steel sheets using silica gel microparticles as surface pre-modifiers: a novel approach to determine selective serotonin reuptake inhibitors in saliva samples by direct infusion tandem mass spectrometry.

Mikrochim Acta

September 2025

Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus Universitario de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.

Stainless-steel substrates have grown in importance in the development of planar sorptive phases. However, the reduced wettability of polished sheets makes difficult their functionalization. This limitation can be solved by using amorphous silica gel microparticles as superficial guides.

View Article and Find Full Text PDF