A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Myoelectric manifestation of muscle fatigue in repetitive work detected by means of miniaturized sEMG sensors. | LitMetric

Myoelectric manifestation of muscle fatigue in repetitive work detected by means of miniaturized sEMG sensors.

Int J Occup Saf Ergon

a Department of Occupational and Environmental Medicine, Epidemiology and Hygiene , INAIL , Italy.

Published: September 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Upper limb work-related musculoskeletal disorders have a 12-month prevalence ranging from 12 to 41% worldwide and can be partly caused by handling low loads at high frequency. The association between the myoelectric manifestation of elbow flexor muscle fatigue and occupational physical demand has never been investigated. It was hypothesized that an elbow flexor muscle fatigue index could be a valid risk indicator in handling low loads at high frequency. This study aims to measure the myoelectric manifestation of muscle fatigue of the three elbow flexor muscles during the execution of the work tasks in different risk conditions. Fifteen right-handed healthy adults were screened using a movement analysis laboratory consisting of optoelectronic, dynamometer and surface electromyographic systems. The main result indicates that the fatigue index calculated from the brachioradialis is sensitive to the interaction among risk classes, session and gender, and above all it is sensitive to the risk classes.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10803548.2017.1357867DOI Listing

Publication Analysis

Top Keywords

muscle fatigue
16
myoelectric manifestation
12
elbow flexor
12
manifestation muscle
8
handling low
8
low loads
8
loads high
8
high frequency
8
flexor muscle
8
risk classes
8

Similar Publications