A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Optimisation of extraction methods and quantification of benzo[a]pyrene and benz[a]anthracene in yerba maté tea by isotope dilution mass spectrometry. | LitMetric

Optimisation of extraction methods and quantification of benzo[a]pyrene and benz[a]anthracene in yerba maté tea by isotope dilution mass spectrometry.

Anal Bioanal Chem

Chemical Metrology Laboratory, Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore.

Published: October 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A gas chromatography-isotope dilution mass spectrometry (GC-IDMS) technique was developed for the quantification of two heavy polyaromatic hydrocarbons (PAHs), benz[a]anthracene and benzo[a]pyrene, in yerba maté tea (maté). The optimisation of two extraction methods, namely liquid-liquid extraction and accelerated solvent extraction, was carried out. Both optimised methods were validated using a certified reference material of fine dust and the results were within the expanded uncertainties at 95% confidence level. Recoveries of 99.2-106.7% with RSD of measurements of 1.1-2.3% were achieved for benz[a]anthracene. Recoveries of 95.7-101.9% with RSD of measurements of 0.4-1.4% were achieved for benzo[a]pyrene. The validated methods were applied for the extraction of benz[a]anthracene and benzo[a]pyrene in maté powder from NIST. A metrological approach was undertaken to ensure the traceability of measurement results. The uncertainties associated with the results were rigorously evaluated and also reported herein. Graphical abstract Quantification of benz[a]anthracene and benzo[a]pyrene using IDMS.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-017-0544-yDOI Listing

Publication Analysis

Top Keywords

benz[a]anthracene benzo[a]pyrene
12
optimisation extraction
8
extraction methods
8
yerba maté
8
maté tea
8
dilution mass
8
mass spectrometry
8
rsd measurements
8
benzo[a]pyrene
5
benz[a]anthracene
5

Similar Publications