Mini-beam modes on standard MX beamline BL17U at SSRF.

Rev Sci Instrum

Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, China.

Published: July 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The macromolecular crystallography beamlines at third-generation synchrotron facilities play a central role in solving macromolecular crystal structures and also in understanding the biological function at molecular levels. The MX beamline BL17U at Shanghai Synchrotron Radiation Facility is a typical standard MX beamline with a focused beam size (H × V) of FWHM around 80 μm × 45 μm. However the protein samples brought to the beamline are down to 5-10 m from the important and challenging science project now. These samples require smaller size beam. In order to achieve the mini-size beamline, two mini-beam modes have been developed on BL17U: the pinhole-based mini-beam and the focused mini-beam by compound refractive lens (CRL). Compared to the pinhole-based mode, three times increase in flux is obtained by the CRL mode at a similar beam size. The flux gain obtained by the CRL needs to be considered for data collection strategies. It takes few minutes to switch the beamline from the normal to CRL mini-beam mode.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4991682DOI Listing

Publication Analysis

Top Keywords

mini-beam modes
8
standard beamline
8
beamline bl17u
8
beam size
8
beamline
6
mini-beam
5
modes standard
4
bl17u ssrf
4
ssrf macromolecular
4
macromolecular crystallography
4

Similar Publications

Mini-beam modes on standard MX beamline BL17U at SSRF.

Rev Sci Instrum

July 2017

Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, China.

The macromolecular crystallography beamlines at third-generation synchrotron facilities play a central role in solving macromolecular crystal structures and also in understanding the biological function at molecular levels. The MX beamline BL17U at Shanghai Synchrotron Radiation Facility is a typical standard MX beamline with a focused beam size (H × V) of FWHM around 80 μm × 45 μm. However the protein samples brought to the beamline are down to 5-10 m from the important and challenging science project now.

View Article and Find Full Text PDF

Predicted optical performance of the GM/CA@APS micro-focus beamline.

J Phys Conf Ser

January 2013

Life Sciences Institute, Department of Biological Chemistry, University of Michigan, Ann Arbor, MI 48109, USA.

GM/CA at the APS has developed microcrystallography capabilities for structural biology applications. The robust, quad, mini-beam collimators, which enable users to rapidly select between a 5, 10 or 20 micron diameter beam or a scatter guard for the full focused beam, are coupled with several powerful automated software tools that are built into the beamline control system JBluIce-EPICS. Recent successes at beamlines around the world in solving structures from microcrystals (2 - 10 microns) have led to increased demand for high-intensity micro-focus beams.

View Article and Find Full Text PDF

Hodgkin's disease demonstrates an exquisite sensitivity to chemotherapy and radiation therapy. This necessitates investigation of modes of delivering these modalities in the best possible fashion to improve outcomes. The British National Lymphoma Investigation (BNLI) has conducted randomized trials in advanced Hodgkin's disease for > 30 years.