A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Multi-analyte method development for analysis of brominated flame retardants (BFRs) and PBDE metabolites in human serum. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Commonly, analytical methods measuring brominated flame retardants (BFRs) of different chemical polarities in human serum are labor consuming and tedious. Our study used acidified diatomaceous earth as solid-phase extraction (SPE) adsorbent and defatting material to simultaneously determine the most abundant BFRs and their metabolites with different polarities in human serum samples. The analytes include three types of commercial BFRs, tetrabromobisphenol A (TBBPA), hexabromocyclododecane (HBCD) isomers, and polybrominated biphenyl ethers (PBDEs), and dominant hydroxylated BDE (OH-PBDE) and methoxylated BDE (MeO-PBDE) metabolites of PBDEs. The sample eluents were sequentially analyzed for PBDEs and MeO-BDEs on online gel permeation chromatography/gas chromatography-electron capture-negative ionization mass spectrometry (online GPC GC-ECNI-MS) and for TBBPA, HBCD, and OH-BDEs on liquid chromatography-tandem mass spectrometry (LC-MS/MS). Method recoveries were 67-134% with a relative standard deviation (RSD) of less than 20%. Method detection limits (MDLs) were 0.30-4.20 pg/mL fresh weight (f.w.) for all analytes, except for BDE-209 of 16 pg/mL f.w. The methodology was also applied in a pilot study, which analyzed ten real samples from healthy donors in China, and the majority of target analytes were detected with a detection rate of more than 80%. To our knowledge, it is the first time for us in effectively determining BFRs of most types in one aliquot of human serum samples. This new analytical method is more specific, sensitive, accurate, and time saving for routine biomonitoring of these BFRs and for integrated assessment of health risk of BFR exposure.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-017-0476-6DOI Listing