A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Pharmacokinetics and Pharmacogenomics of Bupropion in Three Different Formulations with Different Release Kinetics in Healthy Human Volunteers. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The purpose of this pharmacokinetics (PK) study was to investigate whether different release kinetics from bupropion hydrochloride (HCl) immediate release (IR), sustained release (SR), and extended release (ER) formulations alter its metabolism and to test the hypothesis that the unsuccessful bioequivalence (BE) study of the higher strength (300 mg) of bupropion HCl ER tablets based on the successful BE study of the lower strength (150 mg) was due to metabolic saturation in the gastrointestinal (GI) lumen. A randomized six-way crossover study was conducted in healthy volunteers. During each period, subjects took a single dose of IR (75/100 mg), SR (100/150 mg), or ER (150/300 mg) formulations of bupropion HCl; plasma samples for PK analysis were collected from 0-96 h for all formulations. In addition, each subject's whole blood was collected for the genotyping of various single-nucleotide polymorphisms (SNPs) of bupropion's major metabolic enzymes. The data indicates that the relative bioavailability of the ER formulations was 72.3-78.8% compared with IR 75 mg. No differences were observed for ratio of the area under the curve (AUC) of metabolite to AUC of parent for the three major metabolites. The pharmacogenomics analysis suggested no statistically significant correlation between polymorphisms and PK parameters of the various formulations. Altogether, these data suggested that the different release kinetics of the formulations did not change metabolites-to-parent ratio. Therefore, the differing BE result between the 150 and 300 mg bupropion HCl ER tablets was unlikely due to the metabolic saturation in the GI lumen caused by different release patterns.

Download full-text PDF

Source
http://dx.doi.org/10.1208/s12248-017-0102-8DOI Listing

Publication Analysis

Top Keywords

release kinetics
12
bupropion hcl
12
300 mg bupropion
8
hcl tablets
8
metabolic saturation
8
formulations
7
release
7
bupropion
5
pharmacokinetics pharmacogenomics
4
pharmacogenomics bupropion
4

Similar Publications