A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Highly Sensitive Detection of Bisphenol A by NanoAptamer Assay with Truncated Aptamer. | LitMetric

Highly Sensitive Detection of Bisphenol A by NanoAptamer Assay with Truncated Aptamer.

ACS Appl Mater Interfaces

Department of Environmental Science and Engineering, Ewha Womans University, Seoul 03760, Republic of Korea.

Published: May 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

For the sensitive quantification of bisphenol A (BPA), we have developed NanoAptamer assay, which employs aptamer and complementary signaling DNA, a set of quantum dots (QD), and magnetic beads (MBs). Signaling DNA-QD was tethered to MB-QD via the aptamer. The affinity of the aptamer to BPA resulted in the release of the signaling DNA-QD from the complex and hence the corresponding decrease in the QD fluorescence measurement signal. Three new aptamers (23, 58, and 24-mer) were designed via truncation of the reference aptamer (73-mer). The sensitivity and selectivity of each aptamer for BPA detection via NanoAptamer assay were investigated. One of the truncated aptamers (24-mer) has shown a significantly better performance (limit of detection, LOD, 0.17 pg/mL) than the reference 73-mer aptamer (LOD, 570 pg/mL). It has also shown the best selectivity for BPA detection over BPA analogues (i.e., bisphenol B, bisphenol C, and diethylstilbestrol). It corresponded to a normalized fluorescence change of 33.7% at the environmentally relevant concentration of 1 ng/mL (1 ppb) BPA; however, the analogues remained unchanged (2.3-3.9%).

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.7b02377DOI Listing

Publication Analysis

Top Keywords

nanoaptamer assay
12
signaling dna-qd
8
aptamer bpa
8
aptamers 24-mer
8
bpa detection
8
bpa analogues
8
aptamer
7
bpa
6
highly sensitive
4
detection
4

Similar Publications