A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Well-balanced system for coronary calcium detection and volume measurement in a low resolution intravascular ultrasound videos. | LitMetric

Well-balanced system for coronary calcium detection and volume measurement in a low resolution intravascular ultrasound videos.

Comput Biol Med

Monitoring and Diagnostic Division, AtheroPoint™, Roseville 95661, CA, USA; Department of Electrical Engineering, University of Idaho (Affl.), ID, USA. Electronic address:

Published: May 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Accurate and fast quantitative assessment of calcium volume is required during the planning of percutaneous coronary interventions procedures. Low resolution in intravascular ultrasound (IVUS) coronary videos poses a threat to calcium detection causing over-estimation in volume measurement. We introduce a correction block that counter-balances the bias introduced during the calcium detection process.

Method: Nineteen patients image dataset (around 40,090 frames), IRB approved, were collected using 40MHz IVUS catheter (Atlantis® SR Pro, Boston Scientific®, pullback speed of 0.5mm/sec). A new set of 20 generalized and well-balanced systems each consisting of three stages: (i) calcium detection, (ii) calibration and (iii) measurement, while ensuring accuracy of four soft classifiers (Threshold, FCM, K-means and HMRF) and workflow speed using five multiresolution techniques (bilinear, bicubic, wavelet, Lanczos, Gaussian Pyramid) were designed. Results of the three calcium detection methods were benchmarked against the Threshold-based method.

Results: All 20 well-balanced systems with calibration block show superior performance. Using calibration block, FCM versus Threshold-based method shows the highest cross-correlation 0.99 (P<0.0001), Jaccard index 0.984±0.013 (P<0.0001), and Dice similarity 0.992±0.007 (P<0.0001). The corresponding area under the curve for four calcium detection techniques is: 1.0, 1.0, 0.97 and 0.93, respectively. The mean overall performance improvement is 38.54% and when adapting calibration block. The mean workflow speed improvement is 62.14% when adapting multiresolution paradigm. Three clinical tests shows consistency, reliability, and stability of our well-balanced system.

Conclusions: A well-balanced system with a combination of Threshold embedded with Lanczos multiresolution was optimal and can be useable in clinical settings.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compbiomed.2017.03.026DOI Listing

Publication Analysis

Top Keywords

calcium detection
20
volume measurement
8
low resolution
8
resolution intravascular
8
intravascular ultrasound
8
well-balanced systems
8
calibration block
8
calcium
6
detection
5
well-balanced system
4

Similar Publications