Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

is an opportunistic environmental mycobacterium belonging to the - complex. Although most commonly associated with pulmonary disease, there has been growing awareness of invasive infections following cardiac surgery. Investigations suggest worldwide spread of a specific clone, associated with contaminated hospital heater-cooler units used during the surgery. Given the global dissemination of this clone, its potential to cause invasive disease, and the laboriousness of current culture-based diagnostic methods, there is a pressing need to develop rapid and accurate diagnostic assays specific for Here, we assessed 354 mycobacterial genome sequences and confirmed that is a phylogenetically coherent group. comparisons indicated six DNA regions present only in We targeted one of these regions and developed a TaqMan quantitative PCR (qPCR) assay for with a detection limit of 100 CFU/ml in whole blood spiked with bacteria. screening against DNA extracted from 40 other mycobacterial species and 22 bacterial species from 21 diverse genera confirmed the -predicted specificity for Screening 33 water samples from heater-cooler units with this assay highlighted the increased sensitivity of PCR compared to culture, with 15 of 23 culture-negative samples positive by qPCR. We have thus developed a robust molecular assay that can be readily and rapidly deployed to screen clinical and environmental specimens for .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5442541PMC
http://dx.doi.org/10.1128/JCM.00197-17DOI Listing

Publication Analysis

Top Keywords

heater-cooler units
8
target-specific assay
4
assay rapid
4
rapid quantitative
4
quantitative detection
4
detection mycobacterium
4
mycobacterium chimaera
4
chimaera dna
4
dna opportunistic
4
opportunistic environmental
4

Similar Publications

This article presents an image dataset of non-tuberculous mycobacteria (NTM) isolated from heater-cooler units (HCU) using the recently developed NTM Elite agar (bioMérieux, Marcy-l'Étoile, France). NTM (e.g.

View Article and Find Full Text PDF

Objective: To enumerate and describe the effect of whole genome sequencing (WGS) on epidemiological investigations of healthcare-associated transmission of nontuberculous mycobacteria (NTM).

Design: Systematic review.

Methods: We performed a literature search using targeted search terms to identify articles meeting inclusion criteria.

View Article and Find Full Text PDF

Mycobacterium chimaera, belonging to the Mycobacterium avium complex, is an opportunistic environmental mycobacterium which has been isolated from medical device water samples such as Heater Cooler Units (HCU). Laboratories currently use culture-based diagnostic methods to detect M. chimaera, but these take a long time to obtain results.

View Article and Find Full Text PDF
Article Synopsis
  • The study assesses the effectiveness of the BD BACTEC™ MGIT™ system for detecting non-tuberculous mycobacteria (NTM) in sanitary water, focusing on samples from heater-cooler units and haemodialysis instruments over a five-year period.
  • A total of 1,369 water samples from HCUs and 747 from dialysis machines were tested, with 261 and 20 cultures yielding NTM, respectively, verified through advanced techniques.
  • Results show that the MGIT system is not only reliable and reproducible for clinical applications but also effective for environmental testing of NTM, detecting concentrations as low as 4 CFU/mL.
View Article and Find Full Text PDF
Article Synopsis
  • The study monitored 29 Maquet heater-cooler units (HCUs) over a 63-month period to track the presence of non-tuberculous mycobacteria (NTM) in response to the replacement of LivaNova devices due to contamination concerns.
  • Results showed a significant increase in NTM positivity, particularly after three years, with 100% of HCU40 and 62% of HU35 devices colonized, primarily by Mycobacterium gordonae.
  • The findings indicate that current disinfection methods using chloramine-T are insufficient, highlighting the need for improved device safety designs and new disinfection protocols.
View Article and Find Full Text PDF