Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To investigate the preoperative assessment value of spectral CT quantitative parameters in lymph node metastasis of gastric cancer.

Methods: From December 2013 to June 2015, clinical and image data of 86 patients with gastric cancer confirmed by gastroscope pathology undergoing preoperative enhanced CT were prospectively collected. Enhanced CT included nonenhanced CT of conventional 120 kVp mode, arterial phase (AP) and venous phase (VP) with GSI mode on Discover GSI CT scanner. The raw data were transferred to ADW4.6 workstation to reconstruct the monochromatic images at 70 keV and iodine-based images in AP and VP with 1.25 mm thickness. The short diameter, long diameter, ratio of short to long diameter, CT attenuation and iodine value of lymph nodes in each phase were measured and recorded. Pathology results were used as golden standard. The spectral CT quantitative parameters of positive and negative lymph nodes were compared by t test and the sensitivity and specificity analyses were performed by ROC curves. This clinical study registration number 81271573.

Results: Among these 86 gastric cancer patients (53 male and 33 female), tumors of 28 cases were in upper part, of 12 cases in middle part, of 27 cases in distal part and of 19 cases involved two parts. Thirty-five cases were differentiated type and 51 cases were undifferentiated type. A total of 1 072 lymph nodes were found in operation, of which 412 nodes were positive and 660 were negative. Among 552 lymph nodes found in CT images, 338 nodes were positive and 214 were negative. Compared to negative lymph nodes, short diameter [(9.52±3.58) mm vs. (6.48±2.94) mm, t=4.639, P=0.000], ratio of short to long diameter (0.82±0.14 vs. 0.61±0.08, t=13.514, P=0.000), CT attenuation in precontrast [(20.44±6.77) Hu vs. (16.06±7.14) Hu, t=3.154, P=0.002], CT attenuation in AP[(61.71±11.78) Hu vs. (40.11±10.18) Hu, t=9.588, P=0.000], CT attenuation in VP[(71.34±13.03) Hu vs. (53.81±11.39) Hu, t=7.888, P=0.000], iodine value in AP [(16.17±4.22) 100 μg/cm vs. (8.03±3.10) 100 μg/cm, t=9.781, P=0.000], the iodine value in VP [(20.13±6.04) 100 μg/cm vs. (11.58±4.13) 100 μg/cm, t=10.147, P=0.000] of positive lymph nodes were greater. The long diameter was not significantly different between positive and negative lymph nodes [(11.71±5.63) mm vs. (10.64±3.20) mm, t=1.380, P=0.169]. The area under ROC curve of short diameter, ratio of short to long diameter, CT attenuation in precontrast, AP and VP, iodine value in AP and VP of lymph nodes was 0.600, 0.880, 0.648, 0.832, 0.755, 0.864, 0.835, respectively. Taking the ratio of short to long diameter over 0.72 as diagnosis standard, the sensitivity was 75.6% and the specificity was 93.5%. Taking the CT number in AP over 49.75 Hu, the sensitivity was 66.9% and the specificity was 88.8%. Taking the CT number in VP over 59.80 Hu, the sensitivity was 69.9% and the specificity was 77.6%. Taking the iodine value in AP over 9.65 (100 μg/cm), the sensitivity was 80.4% and the specificity was 82.2%. Taking the iodine value in VP over 15.65 (100 μg/cm), the sensitivity was 69.9% and the specificity was 86.9%. Combinong the ratio of short to long diameter with the iodine value in AP, the sensitivity was 95.2% and the specificity was 76.9%.

Conclusions: The ratio of short to long diameter, the iodine value and CT attenuation in AP and VP of lymph nodes in spectral CT are important criteria to evaluate the metastasis of gastric cancer. Combining the ratio of short to long diameter with the iodine value in AP can obviously improve the sensitivity.

Download full-text PDF

Source

Publication Analysis

Top Keywords

long diameter
36
lymph nodes
36
ratio short
28
short long
28
100 μg/cm
24
spectral quantitative
12
quantitative parameters
12
metastasis gastric
12
gastric cancer
12
diameter
12

Similar Publications

To evaluate long‑term outcomes of corneal patch grafting (CPG) and to determine prognostic factors for anatomical and functional success. This retrospective study included 35 eyes from 35 patients who underwent CPG between April 2016 and September 2022 at Adana City Training and Research Hospital. Collected data included age, sex, preoperative and postoperative best-corrected visual acuity (BCVA), graft localization and size, anterior segment findings, graft survival, secondary surgical procedures, and rates of anatomical and functional success.

View Article and Find Full Text PDF

A novel medium-current (up to 20 mA), low normalized beam emittance (<1 π mm mrad) electron cyclotron resonance microwave H+ ion source has been developed at the Center for Energy Research in Budapest, Hungary. This high-stability design targets an energy ripple below 1% while delivering a continuous or pulsed proton beam with adjustable pulse duration (0.1-10 ms) and frequency (0.

View Article and Find Full Text PDF

Background: Greater deposits of epicardial adipose tissue are associated with atrial fibrillation and coronary disease, but have not been studied in subsistence populations.

Methods: We performed CT imaging to measure coronary artery and thoracic aortic calcium (CAC, TAC), epicardial fat thickness (EFT), liver density, and left atrial (LA) anteroposterior diameter and, using a deep learning-enabled software program, epicardial and thoracic fat volume (EFV, TFV), in two remote Amerindian subsistence populations with minimal coronary artery calcification and virtually no atrial fibrillation. We compared 893 adult Tsimane (mean age 58.

View Article and Find Full Text PDF

Fast Scan Cyclic Voltammetry (FSCV) is a widely used electrochemical technique to detect rapid extracellular dopamine transients . It employs carbon fiber microelectrodes (CFMEs), but conventional 7 µm diameter CFMEs often suffer from limited mechanical durability and reduced lifespan, hindering their use in chronic monitoring. To improve mechanical robustness and long-term functionality, we fabricated 30 µm diameter CFMEs and modified their geometry via electrochemical etching to form cone-shaped tips.

View Article and Find Full Text PDF

Background: Sedentary office work poses risks to physical and cognitive health. This study investigated the effects of a 6-month yoga intervention on sedentary office workers' cognitive function and vascular parameters.

Materials And Methods: Twenty-four office workers (mean age 26.

View Article and Find Full Text PDF