A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Variation of flow rate and angle of injected venous needle on influencing intimal hyperplasia at the venous anastomosis of the hemodialysis graft. | LitMetric

Variation of flow rate and angle of injected venous needle on influencing intimal hyperplasia at the venous anastomosis of the hemodialysis graft.

Australas Phys Eng Sci Med

Key Laboratory of Biological Science and Technology (Chongqing University), Ministry of Education, College of Bioengineering of Chongqing University, Shapingba, Chongqing, 400030, China.

Published: March 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

During hemodialysis, arteriovenous (AV) grafts tends to result in intimal hyperplasia (IH) at the venous anastomosis which leads to graft failure. It is well documented that hemodynamic factors have been implicated in IH, as well as pathogenesis of graft stenosis. In this paper, we investigate the flow rate and angle of injection of a venous needle on damaging the hemodialysis graft. Such damage is mainly caused by hemodynamics rather than the actual physical puncture of the needle. By computational fluid dynamic analysis of flow through the AV grafts, we demonstrate that slower flow rate of the needle preserve a larger region of low wall shear stress (WSS). High needle flow angle and fast flow rate tends to induce high shearing of blood against the graft wall, and therefore resulting in a concentrated region of high WSS. Despite that, the increased flow rate causes more significant change to wall shear stress gradient than the flow angle. Obviously, it is important to optimize the injection rate since a high angle can reduce the size of the injection puncture and have smaller injury for the vessel walls; but a slower injection rate may delay hemodialysis. Therefore, the ideal angle and flow rate of needle is sought in this study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13246-017-0526-6DOI Listing

Publication Analysis

Top Keywords

flow rate
24
rate
8
rate angle
8
intimal hyperplasia
8
hyperplasia venous
8
venous anastomosis
8
hemodialysis graft
8
flow
8
rate needle
8
wall shear
8

Similar Publications