A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

EFFECTS OF THE GENIUM MICROPROCESSOR KNEE SYSTEM ON KNEE MOMENT SYMMETRY DURING HILL WALKING. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Use of the Genium microprocessor knee (MPK) system reportedly improves knee kinematics during walking and other functional tasks compared to other MPK systems. This improved kinematic pattern was observed when walking on different hill conditions and at different speeds. Given the improved kinematics associated with hill walking while using the Genium, a similar improvement in the symmetry of knee kinetics is also feasible. The purpose of this study was to determine if Genium MPK use would reduce the degree of asymmetry (DoA) of peak stance knee flexion moment compared to the C-Leg MPK in transfemoral amputation (TFA) patients. This study used a randomized experimental crossover of TFA patients using Genium and C-Leg MPKs ( = 20). Biomechanical gait analysis by 3D motion tracking with floor mounted force plates of TFA patients ambulating at different speeds on 5° ramps was completed. Knee moment DoA was significantly different between MPK conditions in the slow and fast uphill as well as the slow and self-selected downhill conditions. In a sample of high-functioning TFA patients, Genium knee system accommodation and use improved knee moment symmetry in slow speed walking up and down a five degree ramp compared with C-Leg. Additionally, the Genium improved knee moment symmetry when walking downhill at comfortable speed. These results likely have application in other patients who could benefit from more consistent knee function, such as older patients and others who have slower walking speeds.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5218509PMC
http://dx.doi.org/10.21300/18.2-3.2016.151DOI Listing

Publication Analysis

Top Keywords

knee moment
16
tfa patients
16
moment symmetry
12
knee
11
genium microprocessor
8
microprocessor knee
8
knee system
8
hill walking
8
walking genium
8
compared c-leg
8

Similar Publications