Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Lipid profiling in nine bacterial species has been accomplished by laser desorption ionization mass spectrometry (LDI-MS) using amorphous silicon (a-Si) thin film with 100 nm thickness. Lipid ions could be generated by LDI on a-Si regardless of ion acquisition modes because of a thermal property of a-Si to govern laser-induced surface heating. In a comparative study of lipid profiling in Bacillus lichemiformis by LDI-MS and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), LDI-MS on a-Si shows a higher efficiency in lipid and lipopeptide detection than MALDI-MS. A total of 53 peaks of lipid ions generated by LDI on a-Si in both acquisition modes for m/z 400-1200 was 1.6 times more than that detected by MALDI-MS using three organic matrices-2,5-dihydroxybenzoic acid, 1,5-diaminonaphthalene, and 2,4,6-trihydroxyacetophenone monohydrate. Also, the authors demonstrate by mass spectrometry imaging (MSI) that LDI-MS provides high detection coverage through whole sample area. MSI results show the detection yield in LDI on a-Si is 94.8% calculated by counting the number of points detected in the analyte ion signal in a whole spot. It means that reproducible detection of lipid ions by LDI-MS is possible even if laser is randomly irradiated at any position within the bacterial sample area applied on a-Si. Lipid profiling by LDI-MS on a-Si was applied to bacterial differentiation of nine bacterial species conducted by performing principal component analysis. Nine bacterial species are successfully distinguishable from each other by LDI-MS lipid profiling.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1116/1.4972416 | DOI Listing |