A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Optimizing CRT - Do We Need More Leads and Delivery Methods. | LitMetric

Optimizing CRT - Do We Need More Leads and Delivery Methods.

J Atr Fibrillation

Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium; Biomedical Research Institute, Faculty of Medicine and Life Sciences, Hasselt University, Diepenbeek, Belgium.

Published: April 2015


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cardiac resynchronization therapy (CRT) is an established therapeutic option in symptomatic heart failure with reduced ejection fraction and evidence of left ventricular (LV) conduction delay (QRS width ≥120 ms), especially when typical left bundle branch block is present. The rationale behind CRT is restoration of aberrant LV electrical activation. As there is considerable heterogeneity of the LV electrical activation pattern among CRT candidates, an individualized approach with targeting of the LV lead in the region of latest electrical activation while avoiding scar tissue may enhance CRT response. Echocardiography, electro anatomic mapping, and cardiac magnetic resonance imaging with late gadolinium enhancement are helpful to guide such targeted LV lead placement. However, an important limitation remains the anatomy of the coronary sinus, which often does not allow concordant LV lead placement in the optimal region. Epicardial LV lead placement through minimal invasive surgery or endocardial LV lead placement through transseptal punction may overcome this limitation, obviously with an increased complication risk. Furthermore, recent pacing algorithms suggest superiority of LV-only versus biventricular pacing in patients with preserved atrio ventricular (AV) conduction and a typical LBBB pattern. Finally, pacing from only one LV site might not overcome the wide electrical dispersion often seen in patients with LV conduction delays. Therefore, multisite pacing has gained significant interest to improve CRT response. The use of multiple LV leads may potentially lead to more favorable reverse remodeling, improved functional capacity and quality of life in CRT candidates, but adverse events and a shorter battery span are more frequent because of the extra lead. The use of one multipolar LV lead increases the number of pacing configurations within the same coronary sinus side branch (within small distances from each other) without the use of an additional lead. Small observational studies suggest that more effective resynchronization can be achieved with this approach. Finally, there are many reasons for non effective CRT delivery in carefully selected patients with an adequately implanted device. Multidisciplinary, post implantation care inside a dedicated CRT clinic ensures optimal CRT delivery, improves response rate and should be considered standard of care.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4956360PMC
http://dx.doi.org/10.4022/jafib.1202DOI Listing

Publication Analysis

Top Keywords

lead placement
16
electrical activation
12
crt
9
lead
9
ventricular conduction
8
crt candidates
8
crt response
8
coronary sinus
8
crt delivery
8
pacing
5

Similar Publications