98%
921
2 minutes
20
Ultrafast vector flow imaging would benefit newborn patients with congenital heart disorders, but still requires thorough validation before translation to clinical practice. This paper investigates 2-D speckle tracking (ST) of intraventricular blood flow in neonates when transmitting diverging waves at ultrafast frame rate. Computational and in vitro studies enabled us to quantify the performance and identify artifacts related to the flow and the imaging sequence. First, synthetic ultrasound images of a neonate's left ventricular flow pattern were obtained with the ultrasound simulator Field II by propagating point scatterers according to 3-D intraventricular flow fields obtained with computational fluid dynamics (CFD). Noncompounded diverging waves (opening angle of 60°) were transmitted at a pulse repetition frequency of 9 kHz. ST of the B-mode data provided 2-D flow estimates at 180 Hz, which were compared with the CFD flow field. We demonstrated that the diastolic inflow jet showed a strong bias in the lateral velocity estimates at the edges of the jet, as confirmed by additional in vitro tests on a jet flow phantom. Furthermore, ST performance was highly dependent on the cardiac phase with low flows (<5 cm/s), high spatial flow gradients, and out-of-plane flow as deteriorating factors. Despite the observed artifacts, a good overall performance of 2-D ST was obtained with a median magnitude underestimation and angular deviation of, respectively, 28% and 13.5° during systole and 16% and 10.5° during diastole.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TUFFC.2016.2596804 | DOI Listing |
AJNR Am J Neuroradiol
September 2025
From the Department of Interventional Radiology (Shuailong Shi, Shuhai Long, Ji Ma, Peijie Lu, Jie Yang, Ye Wang, Tengfei Li), The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China; The School of Life Science and Technology (Zhike Zhang), Xi'an Jiaotong University, Xi'an, China; an
Background And Purpose: Although high-resolution cone-beam computed tomography (HR-CBCT) is used for immediate evaluation of stent apposition, studies using this technique to evaluate flow diverter (FD) endothelialization during follow-up are limited. The study aims to investigate the potential of HR-CBCT in assessing FD endothelialization and identify factors influencing poor endothelialization.
Materials And Methods: The clinical and imaging data of patients with unruptured intracranial aneurysms (UIAs) treated by FDs from March 2019 to October 2023 were retrospectively analyzed.
J Neurol Surg A Cent Eur Neurosurg
September 2025
Neurosurgery, University of Tsukuba Institute of Medicine, Tsukuba, Japan.
Background: Intracranial solitary fibrous tumors (SFTs) are rare mesenchymal tumors often presenting with dural-based lesions. These tumors can exhibit aggressive characteristics with high recurrence rates and extracranial metastasis. While SFTs occasionally invade venous sinuses, cases where the tumor arises within the venous sinus are rare.
View Article and Find Full Text PDFJ R Soc Interface
September 2025
Department of Biological and Environmental Engineering, Cornell University, Ithaca, NY, USA.
Seed dispersal through wind was historically considered a random process; however, plants can influence their dispersal through non-random seed detachment or abscission. Dandelion seeds facing the wind tend to abscise before those facing downwind, yet the mechanism that supports this has remained unclear. We measured the force needed for abscission in different directions and performed imaging of the detachment process.
View Article and Find Full Text PDFObjective: To determine optimal CT perfusion (CTP) imaging parameters for evaluating the canine prostate and to assess the diagnostic utility of CTP combined with cytopathologic evaluation and B-Raf proto-oncogene (BRAF) gene mutation testing in dogs with prostate adenocarcinoma.
Methods: For this study, 10 male dogs were enrolled, comprising 4 healthy Beagles and 6 client-owned dogs with suspected prostatic neoplasia. Computed tomography perfusion was performed in the healthy dogs using varied contrast agent doses and injection durations.
Schizophr Res
September 2025
UHC Sestre Milosrdnice, Department of Psychiatry, Zagreb, Croatia; Catholic University of Croatia, School of Medicine, Zagreb, Croatia.
Objective: Thalamic abnormalities have been associated with clinical and cognitive symptoms of schizophrenia, yet their role in the early stages of the disorder remain unclear. This study aimed to examine and compare thalamic perfusion differences between first-episode schizophrenia (FES) and early-course schizophrenia (ECS), along with their associations with cognitive performance and symptom severity.
Methods: This study included 100 unmedicated schizophrenia patients aged 19-30: 50 FES and 50 ECS (<5 years, ≥2 episodes).