Article Abstract

Objective: The aim of this optimization study was to minimize the acquisition time of 68Ga-HBED-CC-PSMA positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with local and metastatic prostate cancer (PCa) to obtain a sufficient image quality and quantification accuracy without any appreciable loss.

Methods: Twenty patients with PCa were administered intravenously with the 68Ga-HBED-CC-PSMA ligand (mean activity 99 MBq/patient, range 76-148 MBq) and subsequently underwent PET/MRI at, on average, 168 min (range 77-320 min) after injection. PET and MR imaging data were acquired simultaneously. PET acquisition was performed in list mode and PET images were reconstructed at different time intervals (1, 2, 4, 6, 8, and 10 min). Data were analyzed regarding radiotracer uptake in tumors and muscle tissue and PET image quality. Tumor uptake was quantified in terms of the maximum and mean standardized uptake value (SUVmax, SUVmean) within a spherical volume of interest (VOI). Reference VOIs were drawn in the gluteus maximus muscle on the right side. PET image quality was evaluated by experienced nuclear physicians/radiologists using a five-point ordinal scale from 5-1 (excellent-insufficient).

Results: Lesion detectability linearly increased with increasing acquisition times, reaching its maximum at PET acquisition times of 4 min. At this image acquisition time, tumor lesions in 19/20 (95%) patients were detected. PET image quality showed a positive correlation with increasing acquisition time, reaching a plateau at 4-6 min image acquisition. Both SUVmax and SUVmean correlated inversely with acquisition time and reached a plateau at acquisition times after 4 min.

Conclusion: In the applied image acquisition settings, the optimal acquisition time of 68Ga-PSMA-ligand PET/MRI in patients with local and metastatic PCa was identified to be 4 min per bed position. At this acquisition time, PET image quality and lesion detectability reach a maximum while SUVmax and SUVmean do not change significantly beyond this time point.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5068705PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0164392PLOS

Publication Analysis

Top Keywords

acquisition time
28
image quality
20
pet image
16
pet/mri patients
12
patients local
12
local metastatic
12
acquisition
12
suvmax suvmean
12
acquisition times
12
image acquisition
12

Similar Publications

Accurate timing estimates of when participants acquire HIV in HIV prevention trials are necessary for determining antibody levels at acquisition. The Antibody-Mediated Prevention (AMP) Studies showed that a passively administered broadly neutralizing antibody can prevent the acquisition of HIV from a neutralization-sensitive virus. We developed a pipeline for estimating the date of detectable HIV acquisition (DDA) in AMP Study participants using diagnostic and viral sequence data.

View Article and Find Full Text PDF

Introduction: Modern orthopaedic residency training increasingly integrates knowledge, skills, and behavior (KSB), in line with updated American Board of Orthopaedic Surgery (ABOS) and Accreditation Council for Graduate Medical Education (ACGME) guidelines. Developments in simulation technology-including high-fidelity simulators, virtual reality, and data-driven assessment tools-enable programs to target both technical and non-technical competencies. This paper examines how innovations in simulation, curriculum design, and performance assessment are shaping the future of orthopaedic education.

View Article and Find Full Text PDF

Purpose: Fat fraction (FF) quantification in individual muscles using quantitative MRI is of major importance for monitoring disease progression and assessing disease severity in neuromuscular diseases. Undersampling of MRI acquisitions is commonly used to reduce scanning time. The present paper introduces novel unrolled neural networks for the reconstruction of undersampled MRI acquisitions.

View Article and Find Full Text PDF

Survey of a grapevine microbiome through functional metagenomics.

Food Res Int

November 2025

Department of Agricultural, Forest and Food Sciences, University of Turin, Largo Braccini 2, 10095 Grugliasco, Italy; Interdepartmental Centre for Grapevines and Wine Sciences, University of Turin, Corso Enotria 2/C, 12051 Alba, Italy. Electronic address:

Microorganisms colonizing grapevines possess diverse functional capabilities that influence the health, growth, productivity and, consequently, wine quality. In this study, spatial and temporal dynamics of the microbiome of Vitis vinifera cv. Barbera grapevine were determined by shotgun sequencing.

View Article and Find Full Text PDF

Background: Low cerebral perfusion pressure (CPP) has previously been identified as a key prognostic marker after pediatric traumatic brain injury (TBI). Cerebrovascular autoregulation supports stabilization of cerebral blood flow within the autoregulation range. Beyond the upper limit of this range, cerebral blood flow increases with increasing CPP, leading to increased risk of intracranial hypertension and blood-brain barrier disruptions.

View Article and Find Full Text PDF