Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: The goal of this study was to evaluate the feasibility and safety of a robotic-assisted platform (CorPath 200, Corindus Vascular Robotics, Waltham, Massachusetts) for treating peripheral artery disease.

Background: A robotic-assisted platform for percutaneous coronary intervention is available for treating coronary artery disease.

Methods: In this prospective single-arm trial, patients with symptomatic peripheral artery disease (Rutherford class 2 to 5) affecting the femoropoplital artery were enrolled. Endpoints evaluated were: 1) device technical success, defined as successful cannulation of the target vessel with the robotic system; 2) device safety, defined as absence of device related serious adverse event (hospitalization, prolonged hospitalization, life threatening, or resulted in death); and 3) clinical procedural success, defined as <50% residual stenosis without an unplanned switch to manual assistance or device-related serious adverse event in the periprocedural period.

Results: The study enrolled 20 subjects (65.5 ± 9.3 years of age; 70% male) with primarily Rutherford class 2 to 3 (90%) symptoms. A total of 29 lesions (lesion length: 33.1 ± 15.5 mm) were treated with the majority (89.7%) being located in the superficial femoral artery. Device technical success, safety and clinical procedural success were all 100% with provisional stenting required in 34.5% of lesions. Fluoroscopy time (7.1 ± 3.2 min) and contrast use (73.3 ± 9.2 ml) compared favorably with studies in similar patient cohorts. There were no adverse events associated with the use of the robotic system.

Conclusions: These data demonstrate the feasibility and safety of using a robotic-assisted platform for performing peripheral arterial revascularization.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2016.07.002DOI Listing

Publication Analysis

Top Keywords

feasibility safety
8
robotic-assisted platform
8
peripheral artery
8
success defined
8
safety robotic
4
robotic peripheral
4
peripheral vascular
4
vascular interventions
4
interventions results of
4
results of rapid
4

Similar Publications

Strictures are common in inflammatory bowel disease (IBD) and are managed medically and endoscopically, if feasible, due to the risk of surgical complications. While endoscopic balloon dilation (EBD) is often successful, the need for repeat dilation and subsequent surgery is common. Endoscopic stricturotomy (ESt) has gained popularity but has been limited by frequent post-procedural bleeding.

View Article and Find Full Text PDF

Introduction: Physical inactivity and depression are significant public health concerns, often co-occurring and exacerbating one another. Transcranial direct current stimulation (tDCS) has shown promise in enhancing cognitive and affective processes, potentially improving exercise adherence and outcomes in individuals with depressive symptoms. This study aimed to evaluate the feasibility and preliminary within group effects of combining tDCS with an aerobic exercise (AE) intervention to increase physical activity in individuals with elevated depressive symptoms.

View Article and Find Full Text PDF

Background And Aim: The global shift toward antibiotic-free poultry production necessitates sustainable alternatives to conventional growth promoters. Hydrolyzable tannins (HTs) from plants have shown antimicrobial, antioxidant, and gut-modulatory effects, making them promising feed additives. However, reliance on imported tannins from temperate species limits access for tropical producers, especially in Thailand.

View Article and Find Full Text PDF

Objectives: Cervical cancer is a serious threat to women's life and health and has a high mortality rate. Colposcopy is an important method for early clinical cervical cancer screening, but the traditional vaginal dilator has problems such as discomfort in use and cumbersome operation. For this reason, this study aims to design an intelligent vaginal dilatation system to automate colposcopy and enhance patient comfort.

View Article and Find Full Text PDF