Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The caudal zona incerta (cZI) is an increasingly popular deep brain stimulation (DBS) target for the treatment of tremor-predominant disease. The dentatorubrothalamic tract (DRTT) is a white matter fiber bundle that traverses the cZI and can be identified using diffusion-weighted magnetic resonance imaging fiber tractography to ascertain its precise course. In this report, we compare 2 patient cases of cZI DBS, a responder and a nonresponder.

Case Description: Patient 1 (responder) is a 65-year-old man with medically refractory Parkinson disease who underwent bilateral DBS lead placement in the cZI. Postoperatively he demonstrated >90% reduction in baseline tremor and was not limited by stimulation side effects. Postoperative imaging showed correct lead placement in the cZI. Tractography revealed a DRTT within the field of stimulation, bilaterally. Patient 2 (nonresponder) is a 61-year-old man with medically refractory Parkinson disease who also underwent bilateral DBS lead placement in the cZI. He initially demonstrated >90% reduction in baseline tremor but developed disabling dystonia of his left leg and significant slurring of his speech in the months after surgery. Postoperative imaging showed bilateral lead placement in the cZI. Right-sided electrode revision was recommended and resulted in relief of tremor and reduced dystonic side effects. Tractography analysis of the original leads revealed a DRTT with an atypical anterior trajectory and a location outside the field of stimulation. Tractography analysis of the revised lead showed a DRTT within the field of stimulation.

Conclusions: Preoperative diffusion-weighted magnetic resonance imaging fiber tractography imaging of the DRTT has the potential to improve and individualize DBS planning.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2016.08.103DOI Listing

Publication Analysis

Top Keywords

lead placement
16
placement czi
16
magnetic resonance
12
deep brain
8
brain stimulation
8
white matter
8
diffusion-weighted magnetic
8
resonance imaging
8
imaging fiber
8
fiber tractography
8

Similar Publications

The impact of surgeons' visual angle misperception on acetabular cup positioning accuracy: a retrospective multicentre cohort study.

Int J Surg

September 2025

Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.

Background: Precise acetabular cup placement in total hip arthroplasty (THA) heavily relies on surgeons' visual judgment of angles. However, whether inherent visual angle misperception among surgeons affects surgical outcomes remains unclear. This study is the first to reveal that surgeons universally exhibit visual angle misperception, a key factor causing the cup implant positioning deviations in THA.

View Article and Find Full Text PDF

Cardiac resynchronization therapy (CRT) improves outcomes in heart failure, but prior interventions like percutaneous mitral annuloplasty may hinder lead placement. We present a 70-year-old male with ischemic cardiomyopathy and severe functional mitral regurgitation who previously received a Carillon device. Due to coronary sinus inaccessibility, left bundle branch area pacing optimized cardiac resynchronization therapy (LOT-CRT) was performed.

View Article and Find Full Text PDF

Rapid Atrial Pacing After TAVI for Pacemaker Prediction.

Rev Cardiovasc Med

August 2025

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.

Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.

View Article and Find Full Text PDF

Background: Single-position prone transpsoas lateral lumbar interbody fusion (PTP-LLIF) is an evolving minimally invasive surgery technique that merges the biomechanical and anatomical advantages of prone positioning with the LLIF approach. While PTP-LLIF enhances lumbar lordosis restoration and operative efficiency by eliminating patient repositioning, it presents unique ergonomic and visualization challenges for surgeons. This technical report describes a novel modification of the technique using the Teligen camera to improve intraoperative visualization and reduce surgeon fatigue.

View Article and Find Full Text PDF

Posterior lumbar screw fixation is the most common surgical method for lumbar disc herniation, but patients often face multiple complications postoperatively. The occurrence of screw track loosening can lead to fusion failure and even life-threatening screw track extrusion. However, there is currently a lack of animal models specifically targeting changes in the screw track following lumbar screw fixation.

View Article and Find Full Text PDF