Percutaneous Device Closure of Paravalvular Leak: Combined Experience From the United Kingdom and Ireland.

Circulation

From Papworth Hospital NHS Foundation Trust, Cambridge, United Kingdom (P.A.C., L.S., W.R.D., B.S.R.); Queen Elizabeth Hospital, University Hospitals Birmingham, United Kingdom (P.A.C., P.L., P.C., J.d.G.); Institute of Translational Medicine, University of Birmingham, United Kingdom (P.A.C., P.C.);

Published: September 2016


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Paravalvular leak (PVL) occurs in 5% to 17% of patients following surgical valve replacement. Percutaneous device closure represents an alternative to repeat surgery.

Methods: All UK and Ireland centers undertaking percutaneous PVL closure submitted data to the UK PVL Registry. Data were analyzed for association with death and major adverse cardiovascular events (MACE) at follow-up.

Results: Three hundred eight PVL closure procedures were attempted in 259 patients in 20 centers (2004-2015). Patient age was 67±13 years; 28% were female. The main indications for closure were heart failure (80%) and hemolysis (16%). Devices were successfully implanted in 91% of patients, via radial (7%), femoral arterial (52%), femoral venous (33%), and apical (7%) approaches. Nineteen percent of patients required repeat procedures. The target valve was mitral (44%), aortic (48%), both (2%), pulmonic (0.4%), or transcatheter aortic valve replacement (5%). Preprocedural leak was severe (61%), moderate (34%), or mild (5.7%) and was multiple in 37%. PVL improved postprocedure (P<0.001) and was none (33.3%), mild (41.4%), moderate (18.6%), or severe (6.7%) at last follow-up. Mean New York Heart Association class improved from 2.7±0.8 preprocedure to 1.6±0.8 (P<0.001) after a median follow-up of 110 (7-452) days. Hospital mortality was 2.9% (elective), 6.8% (in-hospital urgent), and 50% (emergency) (P<0.001). MACE during follow-up included death (16%), valve surgery (6%), late device embolization (0.4%), and new hemolysis requiring transfusion (1.6%). Mitral PVL was associated with higher MACE (hazard ratio [HR], 1.83; P=0.011). Factors independently associated with death were the degree of persisting leak (HR, 2.87; P=0.037), New York Heart Association class (HR, 2.00; P=0.015) at follow-up and baseline creatinine (HR, 8.19; P=0.001). The only factor independently associated with MACE was the degree of persisting leak at follow-up (HR, 3.01; P=0.002).

Conclusion: Percutaneous closure of PVL is an effective procedure that improves PVL severity and symptoms. Severity of persisting leak at follow-up is independently associated with both MACE and death. Percutaneous closure should be considered as an alternative to repeat surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6485596PMC
http://dx.doi.org/10.1161/CIRCULATIONAHA.116.022684DOI Listing

Publication Analysis

Top Keywords

percutaneous device
8
device closure
8
paravalvular leak
8
valve replacement
8
pvl closure
8
closure
5
pvl
5
closure paravalvular
4
leak combined
4
combined experience
4

Similar Publications

Background: Umbilical arterial catheterisation is a common intervention performed in the neonatal intensive care unit (NICU) especially in extremely preterm and extremely low birth weight neonates. Rarely catheter fracture or breakage can occur, leaving behind part of the catheter in the aorta. A handful of cases have been reported in the literature, with the majority being managed surgically.

View Article and Find Full Text PDF

Background: Lower extremity arterial disease is a prevalent vascular condition leading to ischemic symptoms and increased risk of cardiovascular events. Drug-eluting stents have improved outcomes by reducing restenosis, with sirolimus emerging as a promising alternative to paclitaxel due to its safer profile. This study evaluates the efficacy and safety of novel polymer-free Amphilimus formulation (Sirolimus + fatty acid) eluting self-expanding stent in the treatment of femoropopliteal disease in a real-world population.

View Article and Find Full Text PDF

Purpose: Percutaneous nephrolithotomy (PCNL) is a common technique in the surgical management of renal lithiasis, but it also represents a significant workload for surgeons. Factors such as the patient's position and the type of lithotripter used influence the physical and mental load on the surgeon. The study aimed to identify stressors related to PCNL by comparing the physical and mental workload experienced by urologists during PCNL under different patient positions and using two lithotripters.

View Article and Find Full Text PDF

Objectives: This study aims to assess the efficacy and safety of five categories of intracorporeal lithotripsy devices in percutaneous nephrolithotomy (PCNL): Pneumatic lithotripters, ultrasonic lithotripters, double-probe dual-energy lithotripters, single-probe dual-energy (SPDE) lithotripters and lasers.

Methods: A network meta-analysis was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. PubMed, Embase and Cochrane were utilised to search for randomised controlled trials (RCTs) up to 10 August 2024.

View Article and Find Full Text PDF

Purpose: Pelvic ring fractures involving the iliopubic rami can cause functional impairment. Percutaneous retrograde fixation is a less invasive procedure when compared to traditional open approaches, however precise anatomical knowledge is crucial for safe screw placement. This study aims to describe the morphology of the iliopubic rami, define a safety corridor for percutaneous screw fixation, specially focusing on the relationships between the iliopubic rami and neurovascular structures.

View Article and Find Full Text PDF